Comparison of MRI- and CT-based patient-specific guides for total knee arthroplasty
- PMID: 25199712
- DOI: 10.1016/j.knee.2014.08.015
Comparison of MRI- and CT-based patient-specific guides for total knee arthroplasty
Abstract
Background: The patient-specific guide for total knee arthroplasty (TKA) is created from the data provided by magnetic resonance imaging (MRI) or computed tomography (CT) scans. It remains unknown which imaging technology is suitable for the patient-specific guide. The purpose of this study was to compare the accuracy of implant positioning and operative times between the two types of patient-specific guides for TKA.
Methods: Forty arthritic knees were divided into two treatment groups using MRI-based (PS-MRI group) or CT-based (PS-CT group) patient-specific guides in this prospective, comparative study. The guide in the PS-MRI group had a cutting slot, whereas that in the PS-CT group only had a pin locator. The operative times were compared between the two groups. The angular error and number of outliers (deviations >3°) of the implant position using pre- and postoperative CT were investigated in both groups.
Results: The mean operative time was significantly shorter in the PS-MRI group (109.2 ± 16.5 min) than in the PS-CT group (129.5 ± 19.4 min) (p<0.001). There were no significant differences in the accuracy of the implant position regarding the coronal, sagittal, and axial planes between the groups (p>0.05).
Conclusions: To reduce the operative time, guides with additional functions, such as cutting and positioning, should be used. Both CT- and MRI-based-guides would result in the same accuracy in three planes but high inaccuracy in the sagittal plane. The use of patient-specific guide based on MRI might not be cost-effective.
Level of evidence: level 2.
Keywords: Computed tomography; Magnetic resonance imaging; Patient-specific guide; Patient-specific instrumentation; Total knee arthroplasty.
Copyright © 2014 Elsevier B.V. All rights reserved.
Similar articles
-
A radiological analysis of the difference between MRI- and CT-based patient-specific matched guides for total knee arthroplasty from the same manufacturer: a randomised controlled trial.Bone Joint J. 2016 Jun;98-B(6):786-92. doi: 10.1302/0301-620X.98B6.36633. Bone Joint J. 2016. PMID: 27235521 Clinical Trial.
-
Three-dimensional analysis of accuracy of component positioning in total knee arthroplasty with patient specific and conventional instruments: A randomized controlled trial.Knee. 2017 Dec;24(6):1469-1477. doi: 10.1016/j.knee.2017.08.059. Epub 2017 Sep 21. Knee. 2017. PMID: 28943039 Clinical Trial.
-
Radiographic outcome of limb-based versus knee-based patient specific guides in total knee arthroplasty.Knee. 2014 Dec;21(6):1244-9. doi: 10.1016/j.knee.2014.08.013. Epub 2014 Sep 11. Knee. 2014. PMID: 25218970
-
Improving outcomes in total knee arthroplasty-do navigation or customized implants have a role?J Orthop Surg Res. 2016 May 23;11(1):60. doi: 10.1186/s13018-016-0396-8. J Orthop Surg Res. 2016. PMID: 27216272 Free PMC article. Review.
-
Customized knee arthroplasty and the role of preoperative imaging.AJR Am J Roentgenol. 2013 Sep;201(3):W443-50. doi: 10.2214/AJR.13.10778. AJR Am J Roentgenol. 2013. PMID: 23971475 Review.
Cited by
-
Patient-Specific or Conventional Instrumentations: A Meta-analysis of Randomized Controlled Trials.Biomed Res Int. 2020 Mar 10;2020:2164371. doi: 10.1155/2020/2164371. eCollection 2020. Biomed Res Int. 2020. PMID: 32258107 Free PMC article. Review.
-
No differences in mid-term survival and clinical outcome between CT- and MRI-based patient-specific instrumentation for total knee arthroplasty, a randomized controlled trial.Eur J Orthop Surg Traumatol. 2024 Oct;34(7):3529-3534. doi: 10.1007/s00590-023-03680-1. Epub 2023 Aug 13. Eur J Orthop Surg Traumatol. 2024. PMID: 37573271 Clinical Trial.
-
3D-printing techniques in a medical setting: a systematic literature review.Biomed Eng Online. 2016 Oct 21;15(1):115. doi: 10.1186/s12938-016-0236-4. Biomed Eng Online. 2016. PMID: 27769304 Free PMC article.
-
Abnormal rate of intraoperative and postoperative implant positioning outliers using "MRI-based patient-specific" compared to "computer assisted" instrumentation in total knee replacement.Knee Surg Sports Traumatol Arthrosc. 2016 Nov;24(11):3441-3447. doi: 10.1007/s00167-015-3645-1. Epub 2015 May 21. Knee Surg Sports Traumatol Arthrosc. 2016. PMID: 25994474 Clinical Trial.
-
Structure-enhanced local phase filtering using L0 gradient minimization for efficient semiautomated knee magnetic resonance imaging segmentation.J Med Imaging (Bellingham). 2016 Oct;3(4):044503. doi: 10.1117/1.JMI.3.4.044503. Epub 2016 Dec 2. J Med Imaging (Bellingham). 2016. PMID: 27981068 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials