Rapid dynamic R1 /R2 */temperature assessment: a method with potential for monitoring drug delivery
- PMID: 25208052
- DOI: 10.1002/nbm.3182
Rapid dynamic R1 /R2 */temperature assessment: a method with potential for monitoring drug delivery
Abstract
Local drug delivery by hyperthermia-induced drug release from thermosensitive liposomes (TSLs) may reduce the systemic toxicity of chemotherapy, whilst maintaining or increasing its efficacy. Relaxivity contrast agents can be co-encapsulated with the drug to allow the visualization of the presence of liposomes, by means of R2 *, as well as the co-release of the contrast agent and the drug, by means of R1, on heating. Here, the mathematical method used to extract both R2 * and R1 from a fast dynamic multi-echo spoiled gradient echo (ME-SPGR) is presented and analyzed. Finally, this method is used to monitor such release events. R2 * was obtained from a fit to the ME-SPGR data. Absolute R1 was calculated from the signal magnitude changes corrected for the apparent proton density changes and a baseline Look-Locker R1 map. The method was used to monitor nearly homogeneous water bath heating and local focused ultrasound heating of muscle tissue, and to visualize the release of a gadolinium chelate from TSLs in vitro. R2 *, R1 and temperature maps were measured with a 5-s temporal resolution. Both R2 *and R1 measured were found to change with temperature. The dynamic R1 measurements after heating agreed with the Look-Locker R1 values if changes in equilibrium magnetization with temperature were considered. Release of gadolinium from TSLs was detected by an R1 increase near the phase transition temperature, as well as a shallow R2 * increase. Simultaneous temperature, R2 * and R1 mapping is feasible in real time and has the potential for use in image-guided drug delivery studies.
Keywords: MRI; apparent proton density; drug delivery system; focused ultrasound; high-intensity focused ultrasound; multi-echo spoiled gradient echo; relaxometry, R1, R2*; thermosensitive liposome.
Copyright © 2014 John Wiley & Sons, Ltd.
Similar articles
-
Interleaved Mapping of Temperature and Longitudinal Relaxation Rate to Monitor Drug Delivery During Magnetic Resonance-Guided High-Intensity Focused Ultrasound-Induced Hyperthermia.Invest Radiol. 2017 Oct;52(10):620-630. doi: 10.1097/RLI.0000000000000392. Invest Radiol. 2017. PMID: 28598900
-
Magnetic Heating Stimulated Cargo Release with Dose Control using Multifunctional MR and Thermosensitive Liposome.Nanotheranostics. 2019 Apr 19;3(2):166-178. doi: 10.7150/ntno.31164. eCollection 2019. Nanotheranostics. 2019. PMID: 31183312 Free PMC article.
-
Simultaneous T1 measurements and proton resonance frequency shift based thermometry using variable flip angles.Magn Reson Med. 2012 Feb;67(2):457-63. doi: 10.1002/mrm.22987. Epub 2011 Nov 2. Magn Reson Med. 2012. PMID: 22052363
-
Hyperthermia-triggered drug delivery from temperature-sensitive liposomes using MRI-guided high intensity focused ultrasound.J Control Release. 2012 Jul 20;161(2):317-27. doi: 10.1016/j.jconrel.2012.04.041. Epub 2012 May 5. J Control Release. 2012. PMID: 22565055 Review.
-
Magnetic resonance guided high-intensity focused ultrasound for image-guided temperature-induced drug delivery.Adv Drug Deliv Rev. 2014 Jun;72:65-81. doi: 10.1016/j.addr.2014.01.006. Epub 2014 Jan 22. Adv Drug Deliv Rev. 2014. PMID: 24463345 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical