Emergency department rectal temperatures in over 10 years: A retrospective observational study
- PMID: 25215102
- PMCID: PMC4129836
- DOI: 10.5847/wjem.j.issn.1920-8642.2013.02.004
Emergency department rectal temperatures in over 10 years: A retrospective observational study
Abstract
Background: Fever in patients can provide an important clue to the etiology of a patient's symptoms. Non-invasive temperature sites (oral, axillary, temporal) may be insensitive due to a variety of factors. This has not been well studied in adult emergency department patients. To determine whether emergency department triage temperatures detected fever adequately when compared to a rectal temperature.
Methods: A retrospective chart review was made of 27 130 adult patients in a high volume, urban emergency department over an eight-year period who received first a non-rectal triage temperature and then a subsequent rectal temperature.
Results: The mean difference in temperatures between the initial temperature and the rectal temperature was 1.3 °F (P<0.001), with 25.9% of the patients having higher rectal temperatures ≥2 °F, and 5.0% having higher rectal temperatures ≥4 °F. The mean difference among the patients who received oral, axillary, and temporal temperatures was 1.2 °F (P<0.001), 1.8 °F (P<0.001), and 1.2 °F (P<0.001) respectively. About 18.1% of the patients were initially afebrile and found to be febrile by rectal temperature, with an average difference of 2.5 °F (P<0.001). These patients had a higher rate of admission (61.4%, P<0.005), and were more likely to be admitted to the hospital for a higher level of care, such as an intensive care unit, when compared with the full cohort (12.5% vs. 5.8%, P<0.005).
Conclusions: There are significant differences between rectal temperatures and non-invasive triage temperatures in this emergency department cohort. In almost one in five patients, fever was missed by triage temperature.
Keywords: Axillary temperatures; Emergency department; Oral temperatures; Rectal temperatures.
Conflict of interest statement
Similar articles
-
Temperature measurement in the adult emergency department: oral, tympanic membrane and temporal artery temperatures versus rectal temperature.Emerg Med J. 2016 Dec;33(12):843-847. doi: 10.1136/emermed-2015-205122. Epub 2016 Jun 22. Emerg Med J. 2016. PMID: 27334759
-
Temporal artery and axillary thermometry comparison with rectal thermometry in children presenting to the ED.Am J Emerg Med. 2017 Dec;35(12):1855-1858. doi: 10.1016/j.ajem.2017.06.017. Epub 2017 Jun 11. Am J Emerg Med. 2017. PMID: 28641982
-
Do Bacteremic patients with end-stage renal disease have a fever when presenting to the emergency department? A paired, retrospective cohort study.BMC Emerg Med. 2020 Jan 9;20(1):2. doi: 10.1186/s12873-019-0298-2. BMC Emerg Med. 2020. PMID: 31918657 Free PMC article.
-
Comparison of temporal artery thermometry and rectal thermometry in febrile pediatric emergency department patients.Pediatr Emerg Care. 2013 Mar;29(3):301-4. doi: 10.1097/PEC.0b013e3182850421. Pediatr Emerg Care. 2013. PMID: 23426242
-
Temperature.In: Walker HK, Hall WD, Hurst JW, editors. Clinical Methods: The History, Physical, and Laboratory Examinations. 3rd edition. Boston: Butterworths; 1990. Chapter 218. In: Walker HK, Hall WD, Hurst JW, editors. Clinical Methods: The History, Physical, and Laboratory Examinations. 3rd edition. Boston: Butterworths; 1990. Chapter 218. PMID: 21250173 Free Books & Documents. Review.
Cited by
-
Clinical accuracy of infrared temperature measurement devices: a comparison against non-invasive core-body temperature.Clin Med (Lond). 2023 Mar;23(2):157-163. doi: 10.7861/clinmed.2022-0252. Clin Med (Lond). 2023. PMID: 36958833 Free PMC article.
-
Regression model for predicting core body temperature in infrared thermal mass screening.IPEM Transl. 2022 Nov-Dec;3:100006. doi: 10.1016/j.ipemt.2022.100006. Epub 2022 Jul 15. IPEM Transl. 2022. PMID: 35854880 Free PMC article.
-
The Utility of Blood Cultures in Non-Febrile Patients and Patients with Antibiotics Therapy in Internal Medicine Departments.J Clin Med. 2025 Mar 30;14(7):2373. doi: 10.3390/jcm14072373. J Clin Med. 2025. PMID: 40217823 Free PMC article.
References
-
- Blainey CG. Site selection in taking body temperature. Am J Nurs. 1974;74:1859–1861. - PubMed
-
- Rotello LC, Crawford L, Terndrup TE. Comparison of infrared ear thermometer derived and equilibrated rectal temperatures in estimating pulmonary artery temperatures. Crit Care Med. 1996;24:1501–1506. - PubMed
-
- Schmitz T, Bair N, Falk M, Levine C. A comparison of five methods of temperature measurement in febrile intensive care patients. Am J Crit Care. 1995;4:286–292. - PubMed
-
- Neff J, Ayoub J, Longman A, Noyes A. Effect of respiratory rate, respiratory depth, and open versus closed mouth breathing on sublingual temperature. Res Nurs Health. 1989;12:195–202. - PubMed
-
- Quatrara B, Coffman J, Jenkins T, Mann K, McGough K, Conaway M, et al. The effect of respiratory rate and ingestion of hot and cold beverages on the accuracy of oral temperatures measured by electronic thermometers. Medsurg Nurs. 2007;16:105–108. 100. - PubMed
LinkOut - more resources
Full Text Sources