A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism
- PMID: 25217037
- DOI: 10.1007/s00380-014-0578-4
A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism
Abstract
Simultaneous dual-isotope SPECT imaging with 201Tl and (123)I-β-methyl-p-iodophenylpentadecanoic acid (BMIPP) is used to study the perfusion-metabolism mismatch. It predicts post-ischemic functional recovery by detecting stunned myocardium. On the other hand, (99m)Tc-MIBI is another radioisotope widely used in myocardial perfusion imaging because of its better image quality and lower radiation exposure than 201Tl. However, since the photopeak energies of (99m)Tc and (123)I are very similar, crosstalk hampers the simultaneous use of these two radioisotopes. To overcome this problem, we conducted simultaneous dual-isotope imaging study using the D-SPECT scanner (Spectrum-Dynamics, Israel) which has a novel detector design and excellent energy resolution. We first conducted a basic experiment using cardiac phantom to simulate the condition of normal perfusion and impaired fatty acid metabolism. Subsequently, we prospectively recruited 30 consecutive patients who underwent successful percutaneous coronary intervention for acute myocardial infarction, and performed (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging within 5 days after reperfusion. Images were interpreted by two experienced cardiovascular radiologists to identify the infarcted and stunned areas based on the coronary artery territories. As a result, cardiac phantom experiment revealed no significant crosstalk between (99m)Tc and (123)I. In the subsequent clinical study, (99m)Tc-MIBI/(123)I-BMIPP dual-isotope imaging in all participant yielded excellent image quality and detected infarcted and stunned areas correctly when compared with coronary angiographic findings. Furthermore, we were able to reduce radiation exposure to significantly approximately one-eighth. In conclusion, we successfully demonstrated the practical application of simultaneous assessment of myocardial perfusion and fatty acid metabolism by (99m)Tc-MIBI and (123)I-BMIPP using a D-SPECT cardiac scanner. Compared with conventional (201)TlCl/(123)I-BMIPP dual-isotope imaging, the use of (99m)Tc-MIBI instead of (201)TlCl improves image quality as well as lowers radiation exposure.
Keywords: 99mTc-MIBI; BMIPP; CZT camera; Perfusion–metabolism mismatch; Simultaneous dual-isotope imaging.
Similar articles
-
Simultaneous dual-isotope imaging based on an artificial neural network for evaluating myocardial perfusion and fatty acid metabolism.J Nucl Cardiol. 2013 Jun;20(3):396-405. doi: 10.1007/s12350-013-9699-x. Epub 2013 Mar 5. J Nucl Cardiol. 2013. PMID: 23460077
-
Feasibility of simultaneous 99mTc-tetrofosmin and 123I-BMIPP dual-tracer imaging with cadmium-zinc-telluride detectors in patients undergoing primary coronary intervention for acute myocardial infarction.J Nucl Cardiol. 2021 Feb;28(1):187-195. doi: 10.1007/s12350-018-01585-9. Epub 2019 Jan 2. J Nucl Cardiol. 2021. PMID: 30603890
-
Comparison of 99mTc-sestamibi-18F-fluorodeoxyglucose dual isotope simultaneous acquisition and rest-stress 99mTc-sestamibi single photon emission computed tomography for the assessment of myocardial viability.Nucl Med Commun. 2003 Mar;24(3):251-7. doi: 10.1097/00006231-200303000-00004. Nucl Med Commun. 2003. PMID: 12612465
-
[Progress in nuclear cardiology: new imaging beyond perfusion and function].Nihon Igaku Hoshasen Gakkai Zasshi. 1999 Oct;59(12):656-62. Nihon Igaku Hoshasen Gakkai Zasshi. 1999. PMID: 10565167 Review. Japanese.
-
Technetium-99m Radiopharmaceuticals for Ideal Myocardial Perfusion Imaging: Lost and Found Opportunities.Molecules. 2022 Feb 10;27(4):1188. doi: 10.3390/molecules27041188. Molecules. 2022. PMID: 35208982 Free PMC article. Review.
Cited by
-
Comparative Cardiac Phantom Study Using Tc-99m/I-123 and Tl-201/I-123 Tracers with Cadmium-Zinc-Telluride Detector-Based Single-Photon Emission Computed Tomography.Nucl Med Mol Imaging. 2019 Feb;53(1):57-63. doi: 10.1007/s13139-018-0559-0. Epub 2018 Dec 12. Nucl Med Mol Imaging. 2019. PMID: 30828402 Free PMC article.
-
Creation and characterization of normal myocardial perfusion imaging databases using the IQ·SPECT system.J Nucl Cardiol. 2018 Aug;25(4):1328-1337. doi: 10.1007/s12350-016-0770-2. Epub 2017 Jan 3. J Nucl Cardiol. 2018. PMID: 28050865
-
Roadmap on nanomedicine.Nanotechnology. 2021 Jan 1;32(1):012001. doi: 10.1088/1361-6528/abaadb. Nanotechnology. 2021. PMID: 33043901 Free PMC article.
-
Cadmium Telluride Semiconductor Detector for Improved Spatial and Energy Resolution Radioisotopic Imaging.World J Nucl Med. 2017 Apr-Jun;16(2):101-107. doi: 10.4103/1450-1147.203079. World J Nucl Med. 2017. PMID: 28553175 Free PMC article. Review.
-
Novel SPECT Technologies and Approaches in Cardiac Imaging.Cardiovasc Innov Appl. 2016 Dec 1;2(1):31-46. doi: 10.15212/CVIA.2016.0052. Cardiovasc Innov Appl. 2016. PMID: 29034066 Free PMC article.
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials