REPLACE DARE (Death After Replacement Evaluation) score: determinants of all-cause mortality after implantable device replacement or upgrade from the REPLACE registry
- PMID: 25221331
- DOI: 10.1161/CIRCEP.114.001671
REPLACE DARE (Death After Replacement Evaluation) score: determinants of all-cause mortality after implantable device replacement or upgrade from the REPLACE registry
Abstract
Background: Identifying factors predictive of mortality may be important to decrease risk associated with cardiac implantable electrical device (CIED) replacement procedures. This study aimed to determine whether clinical factors and complications independently associate with death and to develop a mortality risk prediction tool after CIED replacement.
Methods and results: The prospective REPLACE Registry determined 6-month complication and mortality rates after CIED replacement with or without planned lead addition or revision. Vital status was collected. Kaplan-Meier survival and multivariable Cox proportional hazards regression analyses were performed to identify patient, procedural, or complication variables predictive of death. The REPLACE DARE (Death After Replacement Evaluation) Score was constructed using hazard ratios, reflecting relative risk contributions of each variable, combined into an additive mortality risk score equation. At 6 months, 70 of 1744 (4.0%) patients had died. Cox regression analysis found no significant association between major complications and death. However, recent heart failure admission, New York Heart Association class III/IV, antiarrhythmic drug use, cerebrovascular disease, and chronic kidney disease stage were independently associated with 6-month mortality. The REPLACE DARE Score was 2.0±1.4 in survivors versus 3.5±1.8 in nonsurvivors (P<0.001), with predictive receiver operating characteristic value=0.758 (P<0.001). Risk of death was 1.0% for DARE=0 and 55.6% for DARE=7. The hazard ratio was 1.8 for each change of 1 DARE unit.
Conclusions: Comorbidities, but not complications, were significantly associated with mortality after CIED replacement. The REPLACE DARE Score is a novel tool that can identify patients with substantial mortality risk. Such patients should have the relative risk and benefit of their procedure considered carefully.
Clinical trial registration url: http://www.clinicaltrials.gov. Unique identifier: NCT00395447.
Keywords: defibrillators, implantable; mortality; pacemakers.
© 2014 American Heart Association, Inc.
Comment in
-
The REPLACE Death after replacement evaluation score for predicting mortality after device replacement or upgrade: should all implantable devices be replaced?Circ Arrhythm Electrophysiol. 2014 Dec;7(6):997-9. doi: 10.1161/CIRCEP.114.002388. Circ Arrhythm Electrophysiol. 2014. PMID: 25516574 No abstract available.
-
Letter by Lewis et al Regarding Article, "REPLACE DARE (Death After Replacement Evaluation) Score: Determinants of All-Cause Mortality After Implantable Device Replacement or Upgrade From the REPLACE Registry".Circ Arrhythm Electrophysiol. 2015 Apr;8(2):512. doi: 10.1161/CIRCEP.115.002754. Circ Arrhythm Electrophysiol. 2015. PMID: 25900996 No abstract available.
-
Letter by Barra et al Regarding Article, "REPLACE DARE (Death After Replacement Evaluation) Score: Determinants of All-Cause Mortality After Implantable Device Replacement or Upgrade From the REPLACE Registry".Circ Arrhythm Electrophysiol. 2015 Apr;8(2):513. doi: 10.1161/CIRCEP.115.002807. Circ Arrhythm Electrophysiol. 2015. PMID: 25900997 No abstract available.
-
Response to Letter Regarding "REPLACE DARE (Death After Replacement Evaluation) Score: Determinants of All-Cause Mortality After Implantable Device Replacement Or Upgrade From the REPLACE Registry".Circ Arrhythm Electrophysiol. 2015 Apr;8(2):514-5. doi: 10.1161/CIRCEP.115.002777. Circ Arrhythm Electrophysiol. 2015. PMID: 25900998 No abstract available.
Similar articles
-
Rate, causes, and impact on patient outcome of implantable device complications requiring surgical revision: large population survey from two centres in Italy.Europace. 2013 Apr;15(4):531-40. doi: 10.1093/europace/eus337. Epub 2013 Feb 13. Europace. 2013. PMID: 23407627
-
PR interval identifies clinical response in patients with non-left bundle branch block: a Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy substudy.Circ Arrhythm Electrophysiol. 2014 Aug;7(4):645-51. doi: 10.1161/CIRCEP.113.001299. Epub 2014 Jun 24. Circ Arrhythm Electrophysiol. 2014. PMID: 24963007 Clinical Trial.
-
Response to Letter Regarding "REPLACE DARE (Death After Replacement Evaluation) Score: Determinants of All-Cause Mortality After Implantable Device Replacement Or Upgrade From the REPLACE Registry".Circ Arrhythm Electrophysiol. 2015 Apr;8(2):514-5. doi: 10.1161/CIRCEP.115.002777. Circ Arrhythm Electrophysiol. 2015. PMID: 25900998 No abstract available.
-
The efficacy and safety of cardiac resynchronization therapy combined with implantable cardioverter defibrillator for heart failure: a meta-analysis of 5674 patients.Europace. 2013 Jul;15(7):992-1001. doi: 10.1093/europace/eus419. Epub 2013 Feb 17. Europace. 2013. PMID: 23419662 Review.
-
Remote monitoring of cardiac implantable electronic devices (CIED).Trends Cardiovasc Med. 2016 Aug;26(6):568-77. doi: 10.1016/j.tcm.2016.03.012. Epub 2016 Mar 31. Trends Cardiovasc Med. 2016. PMID: 27134007 Free PMC article. Review.
Cited by
-
The Saga of Defibrillation Testing: When Less Is More.Curr Cardiol Rep. 2018 May 5;20(6):44. doi: 10.1007/s11886-018-0987-6. Curr Cardiol Rep. 2018. PMID: 29730796 Review.
-
Implantable cardioverter-defibrillator elective generator replacement: a procedure for all?J Interv Card Electrophysiol. 2016 Mar;45(2):209-18. doi: 10.1007/s10840-015-0087-0. Epub 2016 Jan 12. J Interv Card Electrophysiol. 2016. PMID: 26755207
-
Periprocedural hypotension after conscious sedation versus local anesthesia during defibrillator implantation for left ventricular dysfunction: analysis of a national inpatient database in Japan.Heart Vessels. 2020 Jan;35(1):118-124. doi: 10.1007/s00380-019-01462-6. Epub 2019 Jun 27. Heart Vessels. 2020. PMID: 31250130
-
Outcome in patients undergoing upgrade to cardiac resynchronization therapy: predictors of outcome after upgrade to CRT.Heart Vessels. 2020 Jan;35(1):104-109. doi: 10.1007/s00380-019-01449-3. Epub 2019 Jun 21. Heart Vessels. 2020. PMID: 31227877
-
Reassessment of cardiovascular parameters and comorbidities in implantable cardioverter-defibrillator patients at the time of first replacement.Clin Cardiol. 2018 Jan;41(1):57-62. doi: 10.1002/clc.22849. Epub 2018 Jan 22. Clin Cardiol. 2018. PMID: 29355999 Free PMC article.
Publication types