Abstract
Hemispheric brain injury resulting from a stroke is often accompanied by muscle weakness in contralateral limbs. In neurologically intact subjects, appropriate motoneuronal recruitment and rate modulation are utilized to optimize muscle force production. In the present study, we sought to determine whether weakness in an affected hand muscle in stroke survivors is partially attributable to alterations in the control of muscle activation. Specifically, our goal was to characterize whether the surface EMG amplitude was systematically larger as a function of (low) force in paretic hand muscles as compared to contralateral muscles in the same subject. We tested a multifunctional muscle, the first dorsal interosseous (FDI), in multiple directions about the second metacarpophalangeal joint in ten hemiparetic and six neurologically intact subjects. In six of the ten stroke subjects, the EMG-force slope was significantly greater on the affected side as compared to the contralateral side, as well as compared to neurologically intact subjects. An unexpected set of results was a nonlinear relation between recorded EMG and generated force commonly observed in the paretic FDI, even at very low-force levels. We discuss possible experimental as well as physiological factors that may contribute to an increased EMG-force slope, concluding that changes in motor unit (MU) control are the most likely reasons for the observed changes.
Similar articles
-
Abnormal EMG-force slope estimates in the first dorsal interosseous of hemiparetic stroke survivors.Annu Int Conf IEEE Eng Med Biol Soc. 2008;2008:3562-5. doi: 10.1109/IEMBS.2008.4649975. Annu Int Conf IEEE Eng Med Biol Soc. 2008. PMID: 19163478
-
Altered motor unit discharge patterns in paretic muscles of stroke survivors assessed using surface electromyography.J Neural Eng. 2016 Aug;13(4):046025. doi: 10.1088/1741-2560/13/4/046025. Epub 2016 Jul 19. J Neural Eng. 2016. PMID: 27432656 Free PMC article.
-
Power spectral analysis of surface electromyography (EMG) at matched contraction levels of the first dorsal interosseous muscle in stroke survivors.Clin Neurophysiol. 2014 May;125(5):988-94. doi: 10.1016/j.clinph.2013.09.044. Epub 2013 Nov 21. Clin Neurophysiol. 2014. PMID: 24268816 Clinical Trial.
-
EMG-force relations during isometric contractions of the first dorsal interosseous muscle after stroke.Top Stroke Rehabil. 2013 Nov-Dec;20(6):537-44. doi: 10.1310/tsr2006-537. Top Stroke Rehabil. 2013. PMID: 24273301
-
Impaired motor unit control in paretic muscle post stroke assessed using surface electromyography: a preliminary report.Annu Int Conf IEEE Eng Med Biol Soc. 2012;2012:4116-9. doi: 10.1109/EMBC.2012.6346872. Annu Int Conf IEEE Eng Med Biol Soc. 2012. PMID: 23366833
Cited by
-
Recruitment gain of spinal motor neuron pools in cat and human.Exp Brain Res. 2019 Nov;237(11):2897-2909. doi: 10.1007/s00221-019-05628-6. Epub 2019 Sep 6. Exp Brain Res. 2019. PMID: 31492990
-
Motor Unit Properties of the First Dorsal Interosseous in Chronic Stroke Subjects: Concentric Needle and Single Fiber EMG Analysis.Front Physiol. 2018 Dec 3;9:1587. doi: 10.3389/fphys.2018.01587. eCollection 2018. Front Physiol. 2018. PMID: 30559674 Free PMC article.
-
Spatial Dependence of Log-Transformed Electromyography-Force Relation: Model-Based Sensitivity Analysis and Experimental Study of Biceps Brachii.Bioengineering (Basel). 2023 Apr 12;10(4):469. doi: 10.3390/bioengineering10040469. Bioengineering (Basel). 2023. PMID: 37106655 Free PMC article.
-
Electromyography-Force Relation and Muscle Fiber Conduction Velocity Affected by Spinal Cord Injury.Bioengineering (Basel). 2023 Feb 6;10(2):217. doi: 10.3390/bioengineering10020217. Bioengineering (Basel). 2023. PMID: 36829711 Free PMC article.
-
A Virtual Reality Muscle-Computer Interface for Neurorehabilitation in Chronic Stroke: A Pilot Study.Sensors (Basel). 2020 Jul 4;20(13):3754. doi: 10.3390/s20133754. Sensors (Basel). 2020. PMID: 32635550 Free PMC article.
References
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical