Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2013 Jul-Dec;25(3-4):55-7.

Radiation exposure in different cardiac catheterization procedures in cath lab

  • PMID: 25226741

Radiation exposure in different cardiac catheterization procedures in cath lab

Noor-ul-Hadi et al. J Ayub Med Coll Abbottabad. 2013 Jul-Dec.

Abstract

Background: Interventional procedures render cardiologolists and their team members to high doses of radiations. This study was conducted to assess the radiation exposure in various cardiac catheterization procedures.

Methods: This descriptive cross sectional study was conducted at the catheterization laboratory of Lady Reading Hospital Peshawar from November 2008 to December 2009. Patients were categorized into four groups for procedures a. coronary angiography, b. percutaneous coronary intervention (PCI), c. permanent pacemakers (PPM) and d. percutaneous transvenous mitral commisurotomy (PTMC), two groups for operators (consultants and trainees), and three groups for various accesses (femoral, radial and sub-clavian).

Results: A total of 99 patients undergoing cardiac catheterization were studied. Coronary angiography was performed in 52 (52.5%) patients, PCI in 32 (32.3%)), pacemakers in 6 (6.1%), and PTMC in 9 (9.1%) patients. Consultants did 72 (72.7%) procedures and trainees did 27 (27.3%) procedures. Through radial access, 22 (22.2%) procedures were performed, 71 (71.7%) through femoral, and 6 (6.1%) through sub-clavian. The mean radiation dose for coronary angiography was (4907.862 +/- 15231.6358 microGym2), PCI (10375.16 +/- 16083.4385 microGym2), pacemakers (1406.823 +/- 785.489 microGym2), and PTMC (1157.91 +/- 760.437 microGym2). The mean radiation dose for radial (6147.33 +/- 8480.37 microGym2), femoral (6512.58 +/- 16566.73 microGym2), and sub-clavian was (1406.82 +/- 785.48 microGym2). While for various operators consultants (7489.5 +/- 16925.55 microGym2), and trainees (2475.25 +/- 1178.86 microGym2). The mean time for radial (8.59 +/- 7.28 min), femoral (6.95 +/- 6.43 min) and sub-clavian was (8.24 +/- 4.81 min). The mean time for coronary angiography (4.56 +/- 5.32 min), PCI (11.44 +/- 6.92 min), PPM (8.24 +/- 4.81 min), and PTMC (8.28 +/- 5.01 min).

Conclusions: Radiation dose varies substantially across different groups by different operators and different routes.

PubMed Disclaimer

MeSH terms

LinkOut - more resources