. 2014 Dec;19(6):908-13.
doi: 10.1093/icvts/ivu311. Epub 2014 Sep 16.

Sympathetic block by metal clips may be a reversible operation

Affiliations

Sympathetic block by metal clips may be a reversible operation

Lars L Thomsen et al. Interact Cardiovasc Thorac Surg. 2014 Dec.

Abstract

Objectives: Thoracoscopic sympathectomy is now used routinely to treat patients with disabling primary hyperhidrosis or facial blushing. Published results are excellent, but side effects, such as compensatory sweating, are also very frequent. The surgical techniques used and the levels of targeting the sympathetic chain vary tremendously. Most surgeons transect or resect the sympathetic chain, but application of a metal clip that blocks transmission of nerve impulses in the sympathetic chain is used increasingly worldwide. This approach offers potential reversibility if patients regret surgery, but the question of reversibility remains controversial. Two recent experimental studies found severe histological signs of nerve damage 4-6 weeks after clip removal, but they only used conventional histopathological staining methods.

Methods: Thoracoscopic clipping of the sympathetic trunk was performed in adult sheep, and the clip was removed thoracoscopically after 7 days. Following another 4 weeks (n = 6) or 12 weeks (n = 3), the sympathetic trunks were harvested and analysed by conventional and specific nerve tissue immunohistochemical stains (S100, neurofilament protein and synaptophysin). The contralateral sympathetic chains were used as controls.

Results: Conventional and immunohistochemical stains demonstrated severe signs of neural damage on the operated side 4 weeks after clip removal. After 12 weeks, these changes had decreased markedly and conventional histology had almost normalized.

Conclusions: Conventional and immunohistochemical stains confirmed that application of metal clips to the sympathetic chain caused severe histological damage in the sympathetic trunk that remained visible 4 weeks after clip removal. However, after 12 weeks, these signs of damage had clearly decreased, which suggests in theory that application of metal clips to the sympathetic chain is a reversible procedure if only the observation period is prolonged. Further studies with longer periods between application and removal as well as investigations of nerve conduction should be encouraged, because we do not know whether histological reversibility at cellular level translates into physiological reversibility and possible correlation of nerve trauma with the duration of the applied clip.

Keywords: Experimental; Immunohistochemistry; Nerve block; Reversibility; Sympathectomy.