. 2015 Jan;120(1):76-84.
doi: 10.1213/ANE.0000000000000442.

The use of pulse pressure variation and stroke volume variation in spontaneously breathing patients to assess dynamic arterial elastance and to predict arterial pressure response to fluid administration

Affiliations

The use of pulse pressure variation and stroke volume variation in spontaneously breathing patients to assess dynamic arterial elastance and to predict arterial pressure response to fluid administration

Maurizio Cecconi et al. Anesth Analg. 2015 Jan.

Abstract

Background: Dynamic arterial elastance (Eadyn), defined as the pulse pressure variation (PPV) to stroke volume variation (SVV) ratio, has been suggested as a predictor of the arterial pressure response to fluid administration. In this study, we assessed the effectiveness of Eadyn to predict the arterial blood pressure response to a fluid challenge (FC) in preload-dependent, spontaneously breathing patients.

Methods: Patients admitted postoperatively and monitored with the Nexfin monitor (BMEYE, Amsterdam, The Netherlands) were enrolled in the study. Patients were included in the analysis if they were spontaneously breathing and had an increase in cardiac output ≥10% during an FC. Patients were classified according to the increase in mean arterial blood pressure (MAP) after FC into MAP-responders (MAP increase ≥10%) and MAP-nonresponders (MAP increase <10%). Eadyn was continuously calculated from the PPV and SVV values obtained from the monitor.

Results: Thirty-four FCs from 26 patients were studied. Seventeen FCs (50%) induced a positive MAP response. Preinfusion Eadyn was significantly higher in MAP-responders (1.39 ± 0.41 vs 0.85 ± 0.23; P = 0.0001). Preinfusion Eadyn predicted a positive MAP response to FC with an area under the receiver-operating characteristic curve of 0.92 ± 0.04 of standard error (95% confidence interval, 0.78-0.99; P < 0.0001). A preinfusion Eadyn value ≥1.06 (gray zone: 0.9-1.15) discriminated MAP-responders with a sensitivity and specificity of 88.2% (approximate 95% confidence interval, 64%-99%), respectively.

Conclusions: Noninvasive Eadyn, defined as the PPV to SVV ratio, predicted the arterial blood pressure increase to fluid administration in spontaneously breathing, preload-dependent patients.

PubMed Disclaimer

Comment in

  • The Validity of Eadyn in Spontaneously Breathing Patients.
    Vos JJ, Scheeren TW, Kalmar AF. Vos JJ, et al. Anesth Analg. 2015 Nov;121(5):1400. doi: 10.1213/ANE.0000000000000894. Anesth Analg. 2015. PMID: 26484470 No abstract available.
  • In Response.
    Cecconi M, Monge García MI, Pinsky MR, Rhodes A. Cecconi M, et al. Anesth Analg. 2015 Nov;121(5):1400-2. doi: 10.1213/ANE.0000000000000899. Anesth Analg. 2015. PMID: 26484471 No abstract available.

References

    1. Pinsky MR. Both perfusion pressure and flow are essential for adequate resuscitation. Sepsis. 2000;4:143–6
    1. Marik PE, Monnet X, Teboul JL. Hemodynamic parameters to guide fluid therapy. Ann Intensive Care. 2011;1:1
    1. Monge García MI, Gil Cano A, Gracia Romero M. Dynamic arterial elastance to predict arterial pressure response to volume loading in preload-dependent patients. Crit Care. 2011;15:R15
    1. Sunagawa K, Maughan WL, Burkhoff D, Sagawa K. Left ventricular interaction with arterial load studied in isolated canine ventricle. Am J Physiol. 1983;245:H773–80
    1. Vos JJ, Kalmar AF, Struys MM, Wietasch JK, Hendriks HG, Scheeren TW. Comparison of arterial pressure and plethysmographic waveform-based dynamic preload variables in assessing fluid responsiveness and dynamic arterial tone in patients undergoing major hepatic resection. Br J Anaesth. 2013;110:940–6