Observational Study
. 2014 Sep;7(9):1036-44.
doi: 10.1016/j.jcin.2014.04.014.

Periprocedural intracardiac echocardiography for left atrial appendage closure: a dual-center experience

Affiliations
Free article
Observational Study

Periprocedural intracardiac echocardiography for left atrial appendage closure: a dual-center experience

Sergio Berti et al. JACC Cardiovasc Interv. 2014 Sep.
Free article

Abstract

Objectives: This dual-center study sought to demonstrate the utility and safety of intracardiac echocardiography (ICE) in providing adequate imaging guidance as an alternative to transesophageal echocardiography (TEE) during Amplatzer Cardiac Plug device implantation.

Background: Over 90% of intracardiac thrombi in atrial fibrillation originate from the left atrial appendage (LAA). Patients with contraindications to anticoagulation are potential candidates for LAA percutaneous occlusion. TEE is typically used to guide implantation.

Methods: ICE-guided percutaneous LAA closure was performed in 121 patients to evaluate the following tasks typically achieved by TEE: assessment of the LAA dimension for device sizing; guidance of transseptal puncture; verification of the delivery sheath position; confirmation of location and stability of the device before and after release and continuous monitoring to detect procedural complications. In 51 consecutive patients, we compared the measurements obtained by ICE and fluoroscopy to choose the size of the device.

Results: The device was successfully implanted in 117 patients, yielding a technical success rate of 96.7%. Procedural success was achieved in 113 cases (93.4%). Four major adverse events (3 cardiac tamponades and 1 in-hospital transient ischemic attack) occurred. There was significant correlation in the measurements for device sizing assessed by angiography and ICE (r = 0.94, p < 0.0001).

Conclusions: ICE imaging was able to perform the tasks typically provided by TEE during implantation of the Amplatzer Cardiac Plug device for LAA occlusion. Therefore, we provide evidence that the use of ICE offered accurate measurements of LAA dimension in order to select the correct device sizes.

Keywords: atrial fibrillation; intracardiac echocardiography; intraprocedural imaging; left atrial appendage occlusion; transesophageal echocardiography.