Cardiac function after acute support with direct mechanical ventricular actuation in chronic heart failure
- PMID: 25238499
- DOI: 10.1097/MAT.0000000000000147
Cardiac function after acute support with direct mechanical ventricular actuation in chronic heart failure
Abstract
Direct mechanical ventricular actuation (DMVA) exerts direct cardiac compression/decompression and does not require blood contact. The safety and effects of DMVA support in chronically dysfunctional beating hearts in vivo have not been established. This study evaluated hemodynamics and load-independent systolic/diastolic cardiac function before/after acute support (2 hours) using DMVA in small hearts with induced chronic failure. Chronic heart failure was created in seven small dogs (15 ± 2 kg) via either serial coronary microembolizations or right-ventricular overdrive pacing. Dogs were instrumented to measure cardiac output, hemodynamic pressures, left ventricular volumes for pressure-volume analysis via preload reduction. Temporary cardiac support using a DMVA device was instituted for 2 hours. Hemodynamic and mechanical assessments, including dobutamine dose-responses, were compared both before and after support. Hemodynamic indices were preserved with support. Both left-ventricular systolic and diastolic function were improved postsupport, as the slopes of the preload-recruitable stroke work (+29 ± 7%, p < 0.05) and the end-diastolic pressure-volume relationship (EDPVR: -28 ± 9%, p < 0.05) improved post-DMVA support. Diastolic/systolic myocardial reserve, as assessed by responsiveness to dobutamine challenges, was preserved after DMVA support. Short-term DMVA support can safely and effectively sustain hemodynamics, whereas triggering favorable effects on cardiac function in the setting of chronic heart failure. In particular, DMVA support preserved load-independent diastolic function and reserve.
Similar articles
-
Ventricular actuation improves systolic and diastolic myocardial function in the small failing heart.Ann Thorac Surg. 2009 Dec;88(6):1982-8; discussion 1988. doi: 10.1016/j.athoracsur.2009.08.048. Ann Thorac Surg. 2009. PMID: 19932272
-
Maximizing hemodynamic effectiveness of biventricular assistance by direct cardiac compression studied in ex vivo and in vivo canine models of acute heart failure.J Thorac Cardiovasc Surg. 2000 Aug;120(2):379-86. doi: 10.1067/mtc.2000.106986. J Thorac Cardiovasc Surg. 2000. PMID: 10917957
-
Assessment of synchronized direct mechanical ventricular actuation in a canine model of left ventricular dysfunction.ASAIO J. 2000 Nov-Dec;46(6):756-60. doi: 10.1097/00002480-200011000-00019. ASAIO J. 2000. PMID: 11110276
-
Direct mechanical ventricular actuation: a review.Resuscitation. 1991 Feb;21(1):7-23. doi: 10.1016/0300-9572(91)90074-9. Resuscitation. 1991. PMID: 1852068 Review.
-
Hemodynamics of Mechanical Circulatory Support.J Am Coll Cardiol. 2015 Dec 15;66(23):2663-2674. doi: 10.1016/j.jacc.2015.10.017. J Am Coll Cardiol. 2015. PMID: 26670067 Review.
Cited by
-
Compliant Buckled Foam Actuators and Application in Patient-Specific Direct Cardiac Compression.Soft Robot. 2018 Feb;5(1):99-108. doi: 10.1089/soro.2017.0018. Epub 2017 Oct 26. Soft Robot. 2018. PMID: 29412085 Free PMC article.
-
Human Applications of the Anstadt Cup: Implications for Non-Blood-Contacting Biventricular Support.Ann Thorac Surg Short Rep. 2024 Jun 13;2(4):842-847. doi: 10.1016/j.atssr.2024.05.019. eCollection 2024 Dec. Ann Thorac Surg Short Rep. 2024. PMID: 39790597 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical