Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Sep;40(9):398-407.
doi: 10.1016/s1553-7250(14)40052-7.

Impact of a reengineered electronic error-reporting system on medication event reporting and care process improvements at an urban medical center

Impact of a reengineered electronic error-reporting system on medication event reporting and care process improvements at an urban medical center

Donald McKaig et al. Jt Comm J Qual Patient Saf. 2014 Sep.

Abstract

Background: A study was conducted to evaluate the impact of a reengineered approach to electronic error reporting at a 719-bed multidisciplinary urban medical center.

Methods: The main outcome of interest was the monthly reported medication errors during the preimplementation (20 months) and postimplementation (26 months) phases. An interrupted time series analysis was used to describe baseline errors, immediate change following implementation of the current electronic error-reporting system (e-ERS), and trend of error reporting during postimplementation. Errors were categorized according to severity using the National Coordinating Council for Medication Error Reporting and Prevention (NCC MERP) Medication Error Index classifications. Reported errors were further analyzed by reporter and error site.

Results: During preimplementation, the monthly reported errors mean was 40.0 (95% confidence interval [CI]: 36.3-43.7). Immediately following e-ERS implementation, monthly reported errors significantly increased by 19.4 errors (95% CI: 8.4-30.5). The change in slope of reported errors trend was estimated at 0.76 (95% CI: 0.07-1.22). Near misses and no-patient-harm errors accounted for 90% of all errors, while errors that caused increased patient monitoring or temporary harm accounted for 9% and 1%, respectively. Nurses were the most frequent reporters, while physicians were more likely to report high-severity errors. Medical care units accounted for approximately half of all reported errors.

Conclusion: Following the intervention, there was a significant increase in reporting of prevented errors and errors that reached the patient with no resultant harm. This improvement in reporting was sustained for 26 months and has contributed to designing and implementing quality improvement initiatives to enhance the safety of the medication use process.

PubMed Disclaimer

MeSH terms

LinkOut - more resources