Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Dec;60(6):1580-4.
doi: 10.1016/j.jvs.2014.08.071. Epub 2014 Sep 22.

Duplex ultrasound diagnosis of failing stent grafts placed for occlusive disease

Affiliations
Free article

Duplex ultrasound diagnosis of failing stent grafts placed for occlusive disease

Douglas A Troutman et al. J Vasc Surg. 2014 Dec.
Free article

Abstract

Objective: We previously showed that duplex ultrasound (DU) imaging is beneficial in the diagnosis of failing vein and prosthetic grafts performed for arterial occlusive disease. The purpose of this study was to evaluate whether DU imaging can reliably diagnose failing stent grafts (ie, covered stents) placed for arterial occlusive disease.

Methods: Between July 1, 2005, and June 30, 2013, we placed 142 stent grafts in 92 arterial segments (1.5 stent grafts/stenotic artery) for lower extremity occlusive disease in patients who also underwent at least one DU surveillance study documenting a patent stent graft. Stent grafts were placed in 29 iliac and 52 femoropopliteal arteries and in 11 failing infrainguinal bypass grafts. Stent grafts used were Viabahn (W. L. Gore and Associates Inc, Flagstaff, Ariz) in 116 (82%), Wallgraft (Boston Scientific, Natick, Mass) in 23 (16%), Fluency (C. R. Bard Inc, Tempe, Ariz) in 2 (1%), and iCast (Atrium, Hudson, NH) in 1 (1%). Mean follow-up was 16 months (range, 1 week-86 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission accredited noninvasive vascular laboratory at 1 week, then every 3 months the first year, and every 6 months thereafter. DU measured peak systolic velocities (PSVs) and velocity ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries.

Results: We retrospectively classified the following factors as "abnormal DU findings:" focal PSVs >300 cm/s, uniform PSVs <50 cm/s throughout the graft, and a Vr >3.0. Fifteen of 20 patients with one or more of these abnormal DU findings underwent prophylactic intervention (n = 8) or occluded without intervention (n = 7), whereas only two of 72 with normal DU findings occluded (P = .0001). Excluding the eight patients who underwent prophylactic intervention, seven of 12 patients with abnormal DU findings occluded without intervention vs two of 72 with normal DU findings (P = .0001).

Conclusions: These findings suggest that follow-up DU surveillance can predict failure of stent grafts placed for lower extremity occlusive disease. Focal PSVs >300 cm/s, Vr >3.0, and most importantly, uniform PSVs <50 cm/s throughout the stent graft were statistically reliable markers for predicting stent graft thrombosis.