Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2014 Oct;76(8):593-602.
doi: 10.1097/PSY.0000000000000096.

E-health to manage distress in patients with an implantable cardioverter-defibrillator: primary results of the WEBCARE trial

Affiliations
Randomized Controlled Trial

E-health to manage distress in patients with an implantable cardioverter-defibrillator: primary results of the WEBCARE trial

Mirela Habibović et al. Psychosom Med. 2014 Oct.

Abstract

The Web-based distress management program for patients with an implantable cardioverter-defibrillator (ICD; WEBCARE) was developed to mitigate distress and enhance health-related quality of life in ICD patients. This study investigated the treatment effectiveness at 3-month follow-up for generic and disease-specific outcome measures.

Methods: Consecutive patients implanted with a first-time ICD from six hospitals in the Netherlands were randomized to either the "WEBCARE" or the "usual care" group. Patients in the WEBCARE group received a 12-week fixed, six-lesson behavioral treatment based on the problem-solving principles of cognitive behavioral therapy.

Results: Two hundred eighty-nine patients (85% response rate) were randomized. The prevalence of anxiety and depression ranged between 11% and 30% and 13% and 21%, respectively. No significant intervention effects were observed for anxiety (β = 0.35; p = .32), depression (β = -0.01; p = .98) or health-related quality of life (Mental Component Scale: β = 0.19; p = .86; Physical Component Scale: β = 0.58; p = .60) at 3 months, with effect sizes (Cohen d) being small (range, 0.06-0.13). There were also no significant group differences as measured with the disease-specific measures device acceptance (β = -0.37; p = .82), shock anxiety (β = 0.21; p = .70), and ICD-related concerns (β = -0.08; p = .90). No differences between treatment completers and noncompleters were observed on any of the measures.

Conclusions: In this Web-based intervention trial, no significant intervention effects on anxiety, depression, health-related quality of life, device acceptance, shock anxiety, or ICD-related concerns were observed. A more patient tailored approach targeting the needs of different subsets of ICD patients may be warranted.

Trial registration: clinicaltrials.gov. Identifier: NCT00895700.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

Associated data