Imaging of pediatric head injury in the emergency department
- PMID: 25272077
- DOI: 10.1097/PEC.0000000000000227
Imaging of pediatric head injury in the emergency department
Abstract
Objectives: Computed tomography (CT) is the standard for immediate imaging of head-injured children, but it uses radiation that predisposes to malignancy. The study goals were to describe imaging practices in this population and to identify barriers to rapid magnetic resonance imaging (MRI) use.
Methods: A cross-sectional survey of physicians who care for pediatric patients in emergency departments was conducted. Survey questions included hospital characteristics, access to imaging technology, use of imaging studies, and use of radiation reduction practices.
Results: A total of 459 eligible respondents completed the questionnaire, which represented a response rate of 24.1%. Almost all the respondents (97.7%) reported that radiation concerns influence clinical management of children and adolescents with head trauma. Head CT use was more frequently reported than MRI (55.3% vs 1.5% reported use in more than 10% of patients, respectively). Frequent CT use was associated with practice in community hospitals (P = 0.005), whereas pediatric residency training and pediatric volumes greater than 30,000 visits per year were associated with less frequent use (P = 0.015 and P = 0.028, respectively). In 94.5% of the respondents, reported CT was always available compared with 24.3% reporting MRI as always available (P < 0.001). Reported obstacles to MRI as a screening tool for head-injured children included limited scanner availability (93.5%), patient intolerance of MRI (87.2%), and longer acquisition times (83.3%).
Conclusions: Concerns about radiation exposure motivate change of practice in the management of head-injured children and adolescents. Head CT use is greater at hospitals with lower pediatric volumes, community hospitals, and by providers without pediatric residency training. Obstacles to increased use of MRI or head-injured children include availability, patient intolerance, and long scan acquisition times.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical