[Possibilities for use of Scheimpflug technology in cataract surgery]
- PMID: 25278344
- DOI: 10.1007/s00347-013-2961-4
[Possibilities for use of Scheimpflug technology in cataract surgery]
Abstract
Background: Since its first use in geography 100 years ago Scheimpflug photography has undergone much refinement making it a standard technique in anterior segment diagnostics and even surgical therapy. This review presents the perioperative applications of Scheimpflug photography in cataract and refractive lens surgery.
Objectives: Possible perioperative applications of Scheimpflug photography in cataract surgery and refractive lens surgery.
Methods: Selective review of the literature and personal experiences.
Results: In recent years there have been numerous new applications for Scheimpflug photography, with its main use in preoperative diagnostics and surgical planning. There are also useful applications for intraoperative visualization and postoperative counseling.
Conclusion: Multifunctional devices which enable a variety of further examinations besides Scheimpflug technology alone make the use of this technology possible and reasonable even in hospitals and practices without a focus on refractive surgery.
Similar articles
-
[Corneal topography and keratoconus diagnostics with Scheimpflug photography].Ophthalmologe. 2014 Oct;111(10):920-6. doi: 10.1007/s00347-013-2962-3. Ophthalmologe. 2014. PMID: 25278345 Review. German.
-
[Scheimpflug photography for the examination of phakic intraocular lenses].Ophthalmologe. 2014 Oct;111(10):935-41. doi: 10.1007/s00347-013-2963-2. Ophthalmologe. 2014. PMID: 25332044 Review. German.
-
[Scheimpflug procedure].Ophthalmologe. 2014 Oct;111(10):912-3. doi: 10.1007/s00347-013-2959-y. Ophthalmologe. 2014. PMID: 25293396 German. No abstract available.
-
Precision of a new Scheimpflug and Placido-disk analyzer in measuring corneal thickness and agreement with ultrasound pachymetry.J Cataract Refract Surg. 2013 Feb;39(2):219-24. doi: 10.1016/j.jcrs.2012.10.034. Epub 2012 Dec 3. J Cataract Refract Surg. 2013. PMID: 23218819
-
Repeatability, reproducibility, and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement.J Cataract Refract Surg. 2009 Jan;35(1):127-33. doi: 10.1016/j.jcrs.2008.10.019. J Cataract Refract Surg. 2009. PMID: 19101435
Cited by
-
Monitoring of central corneal thickness after phacoemulsification-comparison of statical and rotating Scheimpflug pachymetry, and spectral-domain OCT.Int J Ophthalmol. 2022 Aug 18;15(8):1266-1272. doi: 10.18240/ijo.2022.08.07. eCollection 2022. Int J Ophthalmol. 2022. PMID: 36017056 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical