Generating and using patient-specific whole-body models for organ dose estimates in CT with increased accuracy: feasibility and validation
- PMID: 25288527
- DOI: 10.1016/j.ejmp.2014.09.005
Generating and using patient-specific whole-body models for organ dose estimates in CT with increased accuracy: feasibility and validation
Abstract
The estimation of patient dose using Monte Carlo (MC) simulations based on the available patient CT images is limited to the length of the scan. Software tools for dose estimation based on standard computational phantoms overcome this problem; however, they are limited with respect to taking individual patient anatomy into account. The purpose of this study was to generate whole-body patient models in order to take scattered radiation and over-scanning effects into account. Thorax examinations were performed on three physical anthropomorphic phantoms at tube voltages of 80 kV and 120 kV; absorbed dose was measured using thermoluminescence dosimeters (TLD). Whole-body voxel models were built as a combination of the acquired CT images appended by data taken from widely used anthropomorphic voxel phantoms. MC simulations were performed both for the CT image volumes alone and for the whole-body models. Measured and calculated dose distributions were compared for each TLD chip position; additionally, organ doses were determined. MC simulations based only on CT data underestimated dose by 8%-15% on average depending on patient size with highest underestimation values of 37% for the adult phantom at the caudal border of the image volume. The use of whole-body models substantially reduced these errors; measured and simulated results consistently agreed to better than 10%. This study demonstrates that combined whole-body models can provide three-dimensional dose distributions with improved accuracy. Using the presented concept should be of high interest for research studies which demand high accuracy, e.g. for dose optimization efforts.
Keywords: Accuracy; Computed tomography; Monte Carlo methods; Patient dosimetry; Patient-specific dose estimation.
Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Similar articles
-
Toward automated and personalized organ dose determination in CT examinations - A comparison of two tissue characterization models for Monte Carlo organ dose calculation with a Therapy Planning System.Med Phys. 2019 Feb;46(2):1012-1023. doi: 10.1002/mp.13357. Epub 2019 Jan 15. Med Phys. 2019. PMID: 30582891
-
Influence of z overscanning on normalized effective doses calculated for pediatric patients undergoing multidetector CT examinations.Med Phys. 2007 Apr;34(4):1163-75. doi: 10.1118/1.2710331. Med Phys. 2007. PMID: 17500447
-
On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations.Med Phys. 2008 May;35(5):2018-28. doi: 10.1118/1.2896075. Med Phys. 2008. PMID: 18561678
-
Comparison of organ dosimetry methods and effective dose calculation methods for paediatric CT.Australas Phys Eng Sci Med. 2012 Jun;35(2):117-34. doi: 10.1007/s13246-012-0134-4. Epub 2012 Apr 11. Australas Phys Eng Sci Med. 2012. PMID: 22492218 Review.
-
USE OF ANTHROPOMORPHIC HETEROGENEOUS PHYSICAL PHANTOMS FOR VALIDATION OF COMPUTATIONAL DOSIMETRY OF MEDICAL PERSONNEL AND PATIENTS.Probl Radiac Med Radiobiol. 2020 Dec;25:148-176. doi: 10.33145/2304-8336-2020-25-148-176. Probl Radiac Med Radiobiol. 2020. PMID: 33361833 Review. English, Ukrainian.
Cited by
-
Cumulative radiation dose from medical imaging in paediatric congenital heart disease patients with epicardial cardiac implantable electronic devices.Eur Heart J Imaging Methods Pract. 2024 Jun 13;2(1):qyae060. doi: 10.1093/ehjimp/qyae060. eCollection 2024 Jan. Eur Heart J Imaging Methods Pract. 2024. PMID: 39045197 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical