Imaging visceral adhesion to polymeric mesh using pneumoperitoneal-MRI in an experimental rat model
- PMID: 25294530
- DOI: 10.1007/s00464-014-3843-9
Imaging visceral adhesion to polymeric mesh using pneumoperitoneal-MRI in an experimental rat model
Abstract
Background: Intraperitoneal mesh implantation is often associated with formation of adhesion to the mesh. This experimental study examines the potential of minimally invasive pneumoperitoneal-MRI to assess these adhesions in a preclinical context.
Methods: Uncoated polyethylene terephthalate meshes were placed intraperitoneally in rats, in regard to the caecum previously scraped to promote petechial bleeding and subsequent adhesions. Examinations were performed 2-weeks post mesh implantation using a rodent dedicated high field MRI. Respiratory-triggered T2-weighted images were acquired prior to and after intraperitoneal injection of ~8-10 mL gas to induce a mechanical stress on the abdominal wall.
Results: Adhesions are occasionally seen in sham-operated rats as opposed to rats receiving polyethylene terephthalate meshes. On high-resolution images, meshes can be detected due to their characteristic net shape. However, evidence of adherence is only found if intraperitoneal gas injection is performed, when a ~1-cm elevation of the abdominal wall is observed. When adherence occurs between the mesh and the caecum, the latter remains in contact with the wall. Looser adherences between visceral tissue and meshes are also observed.
Conclusions: T2-weighted pneumoperitoneal-MRI is a powerful tool for assessing adherence after intraperitoneal mesh implantation. According to the mini-invasive procedure adopted here, this approach may allow a temporal follow-up of adherence fate.
Similar articles
-
Impairment of the Peritoneal Surface as a Decisive Factor for Intestinal Adhesions in Intraperitoneal Onlay Mesh Surgery - Introducing a New Rat Model.Int J Med Sci. 2016 Feb 1;13(2):108-12. doi: 10.7150/ijms.14056. eCollection 2016. Int J Med Sci. 2016. PMID: 26941568 Free PMC article.
-
Can magnetisation transfer magnetic resonance imaging help for the follow-up of synthetic hernia composite meshes fate? A pilot study.MAGMA. 2022 Dec;35(6):1021-1029. doi: 10.1007/s10334-022-01016-4. Epub 2022 May 13. MAGMA. 2022. PMID: 35552915
-
Degradation of mesh coatings and intraperitoneal adhesion formation in an experimental model.Br J Surg. 2009 Mar;96(3):305-13. doi: 10.1002/bjs.6446. Br J Surg. 2009. PMID: 19224521
-
Adhesion prevention in ventral hernia repair: an experimental study comparing three lightweight porous meshes recommended for intraperitoneal use.Hernia. 2017 Feb;21(1):115-123. doi: 10.1007/s10029-016-1541-3. Epub 2016 Oct 18. Hernia. 2017. PMID: 27757549
-
Resorbable Synthetic Meshes for Abdominal Wall Defects in Preclinical Setting: A Literature Review.J Surg Res. 2019 May;237:67-75. doi: 10.1016/j.jss.2018.11.054. Epub 2019 Jan 30. J Surg Res. 2019. PMID: 30710881
Cited by
-
Impairment of the Peritoneal Surface as a Decisive Factor for Intestinal Adhesions in Intraperitoneal Onlay Mesh Surgery - Introducing a New Rat Model.Int J Med Sci. 2016 Feb 1;13(2):108-12. doi: 10.7150/ijms.14056. eCollection 2016. Int J Med Sci. 2016. PMID: 26941568 Free PMC article.
-
Can magnetisation transfer magnetic resonance imaging help for the follow-up of synthetic hernia composite meshes fate? A pilot study.MAGMA. 2022 Dec;35(6):1021-1029. doi: 10.1007/s10334-022-01016-4. Epub 2022 May 13. MAGMA. 2022. PMID: 35552915
References
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical