Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Oct;2(5):526-33.
doi: 10.1016/j.jchf.2014.04.014.

Ambulatory extra-aortic counterpulsation in patients with moderate to severe chronic heart failure

Affiliations
Free article

Ambulatory extra-aortic counterpulsation in patients with moderate to severe chronic heart failure

William T Abraham et al. JACC Heart Fail. 2014 Oct.
Free article

Abstract

Objectives: The study sought to assess feasibility, safety, and potential efficacy of a novel implantable extra-aortic counterpulsation system (C-Pulse) in functional class III and ambulatory functional class IV heart failure (HF) patients.

Background: 30% to 40% of HF patients suffer from poor functional status and quality of life (QoL) but are not in need of end-stage treatments. We undertook a multicenter single-arm study to assess the C-Pulse System in such patients.

Methods: New York Heart Association (NYHA) functional class III or ambulatory functional class IV HF patients were eligible. Safety was assessed continuously through 12 months. Efficacy measurements included changes from baseline to 6 and 12 months in NYHA functional class, Minnesota Living with Heart Failure (MLWHF) and Kansas City Cardiomyopathy Questionnaire (KCCQ) scores, 6-min walk distance (6MWD), and exercise peak oxygen consumption (pVO2; 6 months only).

Results: Twelve men and 8 women (56.7 ± 7 years, 34 to 71 years of age) with ischemic (n = 7) or nonischemic (n = 13) cardiomyopathy were implanted. There was no 30-day mortality and no neurological events or myocardial infarctions through 12 months. At 6 months, there were 3 deaths (1 device-related). One-year survival was 85%. At 6 months, C-Pulse produced improvements in NYHA functional class (3.1 ± 0.3 to 1.9 ± 0.7, p = 0.0005), MLWHF (63.6 ± 19.9 to 40.2 ± 23.2, p = 0.0005), and KCCQ scores (43.6 ± 21.1 to 65.6 ± 21.5, p = 0.0002), but not 6MWD (275.5 ± 64.0 to 296.4 ± 104.9, p = NS) or pVO2 (14.5 ± 3.6 to 13.1 ± 4.4, p = NS). Improvements continued at 12 months, with 6MWD change becoming statistically significant (336.5 ± 91.8, p = 0.0425).

Conclusions: Use of C-Pulse in this population is feasible, appears safe, and improves functional status and QoL. A prospective, multicenter, randomized controlled trial is underway. (C-Pulse IDE Feasability Study-A Heart Assist System; NCT00815880).

Keywords: C-Pulse; counterpulsation; extra-aortic; heart failure; multicenter.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

Associated data