Reduced UHMWPE wear using magnesia-stabilized zirconia instead of CoCr femoral components in a knee simulator
- PMID: 25316377
- DOI: 10.1016/j.arth.2014.09.027
Reduced UHMWPE wear using magnesia-stabilized zirconia instead of CoCr femoral components in a knee simulator
Abstract
Magnesia-stabilized zirconia (Mg-PSZ) is stable and maintains a scratch-resistant surface in hip replacement, but is untested in knees. We assessed whether using Mg-PSZ instead of cobalt-chromium (CoCr) femoral components resulted in less tibial insert wear, and evaluated changes in topography and roughness of the femoral components. Inserts bearing against CoCr or Mg-PSZ were tested using standard (9 Mc) and aggressive (6 Mc) waveforms. Femoral component surface topography and roughness were evaluated before and after testing by optical profilometry. When bearing against Mg-PSZ, UHMWPE wear rate decreased by 73% (standard) and by 59% (aggressive conditions). After 15 Mc, CoCr components featured deep scratches, and roughness increased five-fold, while Mg-PSZ components were unchanged. Mg-PSZ femoral components may be indicated for high-demand patients and those with metal sensitivity.
Keywords: ceramic; cobalt chromium; roughness; total knee arthroplasty; wear.
Copyright © 2014 Elsevier Inc. All rights reserved.
Similar articles
-
Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.Clin Orthop Relat Res. 2011 Aug;469(8):2337-45. doi: 10.1007/s11999-011-1800-7. Epub 2011 Feb 11. Clin Orthop Relat Res. 2011. PMID: 21312076 Free PMC article.
-
Cobalt-chromium femoral components developed scratches and released metal debris in simulated wear whereas ceramic femoral components did not.Bone Joint J. 2021 Jun;103-B(6 Supple A):94-101. doi: 10.1302/0301-620X.103B6.BJJ-2020-2429.R1. Bone Joint J. 2021. PMID: 34053284
-
Improved wear performance with crosslinked UHMWPE and zirconia implants in knee simulation.Acta Orthop. 2006 Jun;77(3):505-11. doi: 10.1080/17453670610046479. Acta Orthop. 2006. PMID: 16819693
-
Performance assessment of femoral knee components made from cobalt-chromium alloy and oxidized zirconium.Knee. 2013 Dec;20(6):388-96. doi: 10.1016/j.knee.2013.01.004. Epub 2013 Apr 11. Knee. 2013. PMID: 23583666
-
Third-body abrasive wear of tibial polyethylene inserts combined with metallic and ceramic femoral components in a knee simulator study.Int J Artif Organs. 2013 Jan;36(1):47-55. doi: 10.5301/ijao.5000189. Int J Artif Organs. 2013. PMID: 23335379
Cited by
-
Wear Performance of Calcium Carbonate-Containing Knee Spacers.Materials (Basel). 2017 Jul 15;10(7):805. doi: 10.3390/ma10070805. Materials (Basel). 2017. PMID: 28773164 Free PMC article.
-
Surface texture analysis of different focal knee resurfacing implants after 6 and 12 months in vivo in a goat model.J Orthop Res. 2022 Oct;40(10):2402-2413. doi: 10.1002/jor.25274. Epub 2022 Feb 6. J Orthop Res. 2022. PMID: 35128715 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources