Evaluation of a novel brachial cuff-based oscillometric method for estimating central systolic pressure in hemodialysis patients

Affiliations

Evaluation of a novel brachial cuff-based oscillometric method for estimating central systolic pressure in hemodialysis patients

Pantelis A Sarafidis et al. Am J Nephrol. 2014.

Abstract

Background/aims: Elevated wave reflections and arterial stiffness, as well as ambulatory blood pressure (BP) are independent predictors of cardiovascular risk in end-stage-renal-disease. This study is the first to evaluate in hemodialysis patients the validity of a new ambulatory oscillometric device (Mobil-O-Graph, IEM, Germany), which estimates aortic BP, augmentation index (AIx) and pulse wave velocity (PWV).

Methods: Aortic SBP (aSBP), heart rate-adjusted AIx (AIx(75)) and PWV measured with Mobil-O-Graph were compared with the values from the most widely used tonometric device (Sphygmocor, ArtCor, Australia) in 73 hemodialysis patients. Measurements were made in a randomized order after 10 min of rest in the supine position at least 30 min before a dialysis session. Brachial BP (mercury sphygmomanometer) was used for the calibration of Sphygmocor's waveform.

Results: Sphygmocor-derived aSBP and AIx(75) did not differ from the relevant Mobil-O-Graph measurements (aSBP: 136.3 ± 19.6 vs. 133.5 ± 19.3 mm Hg, p = 0.068; AIx(75): 28.4 ± 9.3 vs. 30.0 ± 11.8%, p = 0.229). The small difference in aSBP is perhaps explained by a relevant difference in brachial SBP used for calibration (146.9 ± 20.4 vs. 145.2 ± 19.9 mm Hg, p = 0.341). Sphygmocor PWV was higher than Mobil-O-Graph PWV (10.3 ± 3.4 vs. 9.5 ± 2.1 m/s, p < 0.01). All 3 parameters estimated by Mobil-O-Graph showed highly significant (p < 0.001) correlations with the relevant measurements of Sphygmocor (aSBP, r = 0.770; AIx(75), r = 0.400; PWV, r = 0.739). The Bland-Altman Plots for aSBP and AIx(75) showed acceptable agreement between the two devices and no evidence of systemic bias for PWV.

Conclusion: As in other populations, acceptable agreement between Mobil-O-Graph and Sphygmocor was evident for aSBP and AIx(75) in hemodialysis patients; PWV was slightly underestimated by Mobil-O-Graph.