. 2015 Jan-Feb;21(1):22-7.
doi: 10.5152/dir.2014.14139.

Vacuum-assisted stereotactic biopsy for isolated BI-RADS 4 microcalcifications: evaluation with histopathology and midterm follow-up results

Affiliations

Vacuum-assisted stereotactic biopsy for isolated BI-RADS 4 microcalcifications: evaluation with histopathology and midterm follow-up results

Mehmet Mahir Atasoy et al. Diagn Interv Radiol. 2015 Jan-Feb.

Abstract

Purpose: The aim of this study was to evaluate the 10-gauge vacuum-assisted stereotactic biopsy (VASB) of isolated Breast Imaging Reporting and Data System (BI-RADS) 4 microcalcifications, using histology and follow-up results.

Methods: From January 2011 to June 2013, VASB was performed on 132 lesions, and 66 microcalcification-only lesions of BI-RADS 4 were included into our study. VASB was performed using lateral decubitis stereotaxy for all patients. Pathologic results of VASB and further surgical biopsies were reviewed retrospectively. Patients who were diagnosed to have benign lesions by VASB were referred for follow-up. VASB and surgical histopathology results were compared to determine the underestimation ratios.

Results: Fifteen out of 66 lesions from 63 patients (median age, 47 years; range, 34-88 years) were identified as malignant by VASB. Pathological results after surgery revealed three cases of invasive ductal carcinoma among the 12 VASB-diagnosed ductal carcinoma in situ (DCIS) lesions, for a DCIS underestimation rate of 25%. The atypical ductal hyperplasia underestimation rate was 0% for the three lesions. The follow-up period was at least 10 months, with an average of 22.7 months for all patients and 21.2 months for patients with VASB-diagnosed benign lesions. None of the patients had malignancy during the follow-ups. The false-negative rate was 0% in the follow-up of 48 patients.

Conclusion: VASB should be the standard method of choice for BI-RADS 4 microcalcifications. This method obviates the need for a surgical procedure in 73% of BI-RADS 4 microcalcification-only patients.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
Flow chart showing the formation of the study group. VASB, vacuum-assisted stereotactic biopsy.
Figure 2.
Figure 2.
a–c. BI-RADS 4A microcalcifications (a) were detected at the right breast of a 46-year-old woman. After VASB procedure with a 10-gauge needle, microcalcifications were removed and air (b) is seen at the biopsy site. A radiopaque marking clip (c) is released, so that possible subsequent operations can be easily planned if required.

References

    1. Bent CK, Bassett LW, D’Orsi CJ, et al. The positive predictive value of BI-RADS microcalcification descriptors and final assessment categories. AJR Am J Roentgenol. 2010;194:1378–1383. - PubMed
    1. Zografos G, Zagouri F, Sergentan TN, et al. Vacuum-assisted breast biopsy in nonpalpable solid breast lesions without microcalcifications: the Greek experience. Diagn Interv Radiol. 2008;14:127–130. - PubMed
    1. Kettritz U, Morack G, Decker T, et al. Stereotactic vacuum-assisted breast biopsies in 500 women with microcalcifications: radiological and pathological correlations. Eur J Radiol. 2005;55:270–276. - PubMed
    1. Liberman L, Gougoutas CA, Zakowski MF, et al. Calcifications highly suggestive of malignancy: comparison of breast biopsy methods. AJR Am J Roentgenol. 2001;177:165–172. - PubMed
    1. Parker SH, Jobe WE, Dennis MA, et al. US-guided automated large-core breast biopsy. Radiology. 1993;187:507–511. - PubMed