Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2014 Aug;30(8):522-5.
doi: 10.3928/1081597X-20140711-04.

Evaluation of femtosecond laser-assisted and manual clear corneal incisions and their effect on surgically induced astigmatism and higher-order aberrations

Randomized Controlled Trial

Evaluation of femtosecond laser-assisted and manual clear corneal incisions and their effect on surgically induced astigmatism and higher-order aberrations

Zoltán Z Nagy et al. J Refract Surg. 2014 Aug.

Abstract

Purpose: To evaluate femtosecond laser-assisted and manual clear corneal incisions and their effect on surgically induced astigmatism (SIA) and corneal higher-order aberrations (HOAs).

Methods: In a prospective randomized study, conventional phacoemulsification with a 2.8-mm clear corneal incision using a disposable keratome was performed in 20 eyes of 20 patients (manual group), and femtosecond laser-assisted cataract surgery with a 2.8-mm biplanar clear corneal tunnel created by a femtosecond laser (LenSx; Alcon Laboratories, Inc., Aliso Viejo, CA) was performed in 20 eyes of 20 patients (femtosecond laser group). Corneal topography readings and corneal wavefront aberrations (diameter: 9.0 mm) were obtained using a Scheimpflug camera (Pentacam HR; Oculus Optikgerate, Wetzlar, Germany) preoperatively and 3 months postoperatively.

Results: There was no significant difference in SIA between the groups (femtosecond laser group: 0.47 ± 0.13 vs manual group: 0.41 ± 0.14; P = .218), but the axis deviation of the SIA axis from the previously planned axis was significantly smaller in the femtosecond laser group compared to the manual group (4.47°± 2.59° vs 7.38°± 4.72°, respectively; P = .048). Corneal HOAs increased significantly in both groups (femtosecond laser group: 0.13 ± 0.09 to 0.18 ± 0.12, P = .025; manual group: 0.13 ± 0.05 to 0.15 ± 0.05, P = .002), but preoperative and postoperative values did not differ significantly between them (P = .472 and .078, respectively). Lower-order and total corneal aberration values remained stable in both groups (P > .05).

Conclusions: There was no difference in SIA and induced HOAs between manual and femtosecond laser-created clear corneal incisions.

PubMed Disclaimer

Publication types