Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Dec;156(12):2245-52; discussion 2252.
doi: 10.1007/s00701-014-2259-6. Epub 2014 Oct 23.

Predictive value of diffusion-weighted MRI for tumor consistency and resection rate of nonfunctional pituitary macroadenomas

Affiliations

Predictive value of diffusion-weighted MRI for tumor consistency and resection rate of nonfunctional pituitary macroadenomas

Maysam Alimohamadi et al. Acta Neurochir (Wien). 2014 Dec.

Abstract

Backgrounds: Firm tumor consistency is one of the most important factors that impede sufficient removal of pituitary macroademoas via a transsphenoidal approach. The utility of diffusion-weighted (DW) magnetic resonance imaging (MRI) in predicting the tumor consistency and successfulness of transsphenoidal resection was evaluated in this study.

Methods: Thirty consecutive primary cases of nonfunctional pituitary macroadenomas were prospectively enrolled. Conventional and DW MRI were done for all the patients and the apparent diffusion coefficient (ADC) values and the signal intensity of the solid tumor were determined. Intraoperative report of tumor consistency, the degree of fibrosis and percentage of collagen content were documented. The 8 weeks postoperative MRI was used for calculation of the tumor resection rate.

Results: The tumor consistency was soft in 10 patients (33.3 %), intermediate in 14 patients (46.7 %) and hard in 6 patients (20 %). The mean collagen content percentage was 10, 23.5 and 66 % (p = 0.009) and the average resection rate was 75, 43 39 % in the three groups respectively (p = 0.001). The mean ADC value was not significantly correlated with the tumor consistency and resection rate. Tumors with isointense to hyperintense signal on DW MRI were more commonly removable by suction and had higher resection rates than those with hypointense signals (p = 0.019). For ADC values within the range of 600-740 × 10(-3) mm(2)/s, a residual volume larger than 20 % of the tumor was more likely.

Conclusions: DW MRI was useful to predict the tumor consistency, collagen content and the chance of removal of pituitary macroadenomas through endoscopic transsphenoidal surgery, and is recommended in the preoperative patient evaluation.