Post-trial anatomical frame alignment procedure for comparison of 3D joint angle measurement from magnetic/inertial measurement units and camera-based systems
- PMID: 25340557
- DOI: 10.1088/0967-3334/35/11/2255
Post-trial anatomical frame alignment procedure for comparison of 3D joint angle measurement from magnetic/inertial measurement units and camera-based systems
Abstract
Magnetic and inertial measurement units (MIMUs) have been widely used as an alternative to traditional camera-based motion capture systems for 3D joint kinematics measurement. Since these sensors do not directly measure position, a pre-trial anatomical calibration, either with the assistance of a special protocol/apparatus or with another motion capture system is required to establish the transformation matrices between the local sensor frame and the anatomical frame (AF) of each body segment on which the sensors are attached. Because the axes of AFs are often used as the rotational axes in the joint angle calculation, any difference in the AF determination will cause discrepancies in the calculated joint angles. Therefore, a direct comparison of joint angles between MIMU systems and camera-based systems is less meaningful because the calculated joint angles contain a systemic error due to the differences in the AF determination. To solve this problem a new post-trial AF alignment procedure is proposed. By correcting the AF misalignments, the joint angle differences caused by the difference in AF determination are eliminated and the remaining discrepancies are mainly from the measurement accuracy of the systems themselves. Lower limb joint angles from 30 walking trials were used to validate the effectiveness of the proposed AF alignment procedure. This technique could serve as a new means for calibrating magnetic/inertial sensor-based motion capture systems and correcting for AF misalignment in scenarios where joint angles are compared directly.
Similar articles
-
Sensor-to-body calibration procedure for clinical motion analysis of lower limb using magnetic and inertial measurement units.J Biomech. 2019 Mar 6;85:224-229. doi: 10.1016/j.jbiomech.2019.01.027. Epub 2019 Jan 21. J Biomech. 2019. PMID: 30732911
-
Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics.Physiol Meas. 2013 Aug;34(8):N63-9. doi: 10.1088/0967-3334/34/8/N63. Epub 2013 Jul 26. Physiol Meas. 2013. PMID: 23893094
-
Joint kinematics estimate using wearable inertial and magnetic sensing modules.Gait Posture. 2008 Nov;28(4):588-95. doi: 10.1016/j.gaitpost.2008.04.003. Epub 2008 May 23. Gait Posture. 2008. PMID: 18502130
-
Determining anatomical frames via inertial motion capture: A survey of methods.J Biomech. 2020 Jun 9;106:109832. doi: 10.1016/j.jbiomech.2020.109832. Epub 2020 May 11. J Biomech. 2020. PMID: 32517995 Review.
-
25 years of lower limb joint kinematics by using inertial and magnetic sensors: A review of methodological approaches.Gait Posture. 2017 Jan;51:239-246. doi: 10.1016/j.gaitpost.2016.11.008. Epub 2016 Nov 5. Gait Posture. 2017. PMID: 27833057 Review.
Cited by
-
Inertial measurement unit-based pose estimation: Analyzing and reducing sensitivity to sensor placement and body measures.J Rehabil Assist Technol Eng. 2019 Jan 14;6:2055668318813455. doi: 10.1177/2055668318813455. eCollection 2019 Jan-Dec. J Rehabil Assist Technol Eng. 2019. PMID: 31245025 Free PMC article.
-
Estimation of Gait Mechanics Based on Simulated and Measured IMU Data Using an Artificial Neural Network.Front Bioeng Biotechnol. 2020 Feb 5;8:41. doi: 10.3389/fbioe.2020.00041. eCollection 2020. Front Bioeng Biotechnol. 2020. PMID: 32117923 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources