Object: Accurate placement of intracranial depth and subdural electrodes is important in evaluating patients with medically refractory epilepsy for possible resection. Confirming electrode locations on postoperative CT scans does not allow for immediate replacement of malpositioned electrodes, and thus revision surgery is required in select cases. Intraoperative CT (iCT) using the Medtronic O-arm device has been performed to detect electrode locations in deep brain stimulation surgery, but its application in epilepsy surgery has not been explored. In the present study, the authors describe their institutional experience in using the O-arm to facilitate accurate placement of intracranial electrodes for epilepsy monitoring.
Methods: In this retrospective study, the authors evaluated consecutive patients who had undergone subdural and/or depth electrode implantation for epilepsy monitoring between November 2010 and September 2012. The O-arm device is used to obtain iCT images, which are then merged with the preoperative planning MRI studies and reviewed by the surgical team to confirm final positioning. Minor modifications in patient positioning and operative field preparation are necessary to safely incorporate the O-arm device into routine intracranial electrode implantation surgery. The device does not obstruct surgeon access for bur hole or craniotomy surgery. Depth and subdural electrode locations are easily identified on iCT, which merge with MRI studies without difficulty, allowing the epilepsy surgical team to intraoperatively confirm lead locations.
Results: Depth and subdural electrodes were implanted in 10 consecutive patients by using routine surgical techniques together with preoperative stereotactic planning and intraoperative neuronavigation. No wound infections or other surgical complications occurred. In one patient, the hippocampal depth electrode was believed to be in a suboptimal position and was repositioned before final wound closure. Additionally, 4 strip electrodes were replaced due to suboptimal positioning. Postoperative CT scans did not differ from iCT studies in the first 3 patients in the series and thus were not obtained in the final 7 patients. Overall, operative time was extended by approximately 10-15 minutes for O-arm positioning, less than 1 minute for image acquisition, and approximately 10 minutes for image transfer, fusion, and intraoperative analysis (total time 21-26 minutes).
Conclusions: The O-arm device can be easily incorporated into routine intracranial electrode implantation surgery in standard-sized operating rooms. The technique provides accurate 3D visualization of depth and subdural electrode contacts, and the intraoperative images can be easily merged with preoperative MRI studies to confirm lead positions before final wound closure. Intraoperative CT obviates the need for routine postoperative CT and has the potential to improve the accuracy of intracranial electroencephalography recordings and may reduce the necessity for revision surgery.
Keywords: DBS = deep brain stimulation; EEG = electroencephalography; electroencephalography; epilepsy; iCT = intraoperative CT; iMRI = intraoperative MRI; image-guided surgery; intraoperative computed tomography.
Similar articles
-
Neuronavigation and fluoroscopy-assisted subdural strip electrode positioning: a simple method to increase intraoperative accuracy of strip localization in epilepsy surgery.J Neurosurg. 2009 Feb;110(2):327-31. doi: 10.3171/2008.6.JNS17611. J Neurosurg. 2009. PMID: 19012488
-
Optimizations and Nuances in Neurosurgical Technique for the Minimization of Complications in Subdural Electrode Placement for Epilepsy Surgery.World Neurosurg. 2015 Oct;84(4):989-97. doi: 10.1016/j.wneu.2015.01.018. Epub 2015 Feb 11. World Neurosurg. 2015. PMID: 25681595
-
The stereotactic approach for mapping epileptic networks: a prospective study of 200 patients.J Neurosurg. 2014 Nov;121(5):1239-46. doi: 10.3171/2014.7.JNS132306. Epub 2014 Aug 22. J Neurosurg. 2014. PMID: 25148007
-
Neuronavigation applied to epilepsy monitoring with subdural electrodes.Neurosurg Focus. 2008 Sep;25(3):E21. doi: 10.3171/FOC/2008/25/9/E21. Neurosurg Focus. 2008. PMID: 18759623 Review.
-
Intracerebral depth electrode monitoring in partial epilepsy: the morbidity and efficacy of placement using magnetic resonance image-guided stereotactic surgery.Neurosurgery. 1996 Aug;39(2):327-33; discussion 333-4. doi: 10.1097/00006123-199608000-00018. Neurosurgery. 1996. PMID: 8832670 Review.
Cited by
-
SEEG assistant: a 3DSlicer extension to support epilepsy surgery.BMC Bioinformatics. 2017 Feb 23;18(1):124. doi: 10.1186/s12859-017-1545-8. BMC Bioinformatics. 2017. PMID: 28231759 Free PMC article.
-
Deep Brain Stimulation: Expanding Applications.Neurol Med Chir (Tokyo). 2015;55(12):861-77. doi: 10.2176/nmc.ra.2015-0172. Epub 2015 Oct 15. Neurol Med Chir (Tokyo). 2015. PMID: 26466888 Free PMC article. Review.
-
Hybrid Fluoroscopic and Neurophysiological Targeting of Responsive Neurostimulation of the Rolandic Cortex.Oper Neurosurg. 2021 Aug 16;21(3):E180-E186. doi: 10.1093/ons/opab182. Oper Neurosurg. 2021. PMID: 34133746 Free PMC article.
-
3-T intraoperative MRI (iMRI) for pediatric epilepsy surgery.Childs Nerv Syst. 2016 Dec;32(12):2415-2422. doi: 10.1007/s00381-016-3263-3. Epub 2016 Oct 18. Childs Nerv Syst. 2016. PMID: 27757571
-
Real-time display of intracranial subdural electrodes and the brain surface during an electrode implantation procedure using permeable film.Surg Neurol Int. 2024 Jun 7;15:190. doi: 10.25259/SNI_74_2024. eCollection 2024. Surg Neurol Int. 2024. PMID: 38974543 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical