Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2015 Apr;21(2):477-85.
doi: 10.1007/s12253-014-9852-0. Epub 2014 Nov 4.

Accuracy and Reproducibility of HER2 Status in Breast Cancer Using Immunohistochemistry: A Quality Control Study in Tuscany Evaluating the Impact of Updated 2013 ASCO/CAP Recommendations

Collaborators, Affiliations
Free article
Comparative Study

Accuracy and Reproducibility of HER2 Status in Breast Cancer Using Immunohistochemistry: A Quality Control Study in Tuscany Evaluating the Impact of Updated 2013 ASCO/CAP Recommendations

S Bianchi et al. Pathol Oncol Res. 2015 Apr.
Free article

Abstract

The correct identification of HER2-positive cases is a key point to provide the most appropriate therapy to breast cancer (BC) patients. We aimed at investigating the reproducibility and accuracy of HER2 expression by immunohistochemistry (IHC) in a selected series of 35 invasive BC cases across the pathological anatomy laboratories in Tuscany, Italy. Unstained sections of each BC case were sent to 12 participating laboratories. Pathologists were required to score according to the Food and Drug Administration (FDA) four-tier scoring system (0, 1+, 2+, 3+). Sixteen and nineteen cases were HER2 non-amplified and amplified respectively on fluorescence in situ hybridization. Among 192 readings of the 16 HER2 non-amplified samples, 153 (79.7%) were coded as 0 or 1+, 39 (20.3%) were 2+, and none was 3+ (false positive rate 0%). Among 228 readings of the 19 HER2 amplified samples, 56 (24.6%) were scored 0 or 1+, 79 (34.6%) were 2+, and 93 (40.8%) were 3+. The average sensitivity was 75.4%, ranging between 47% and 100%, and the overall false negative rate was 24.6%. Participation of pathological anatomy laboratories performing HER2 testing by IHC in external quality assurance programs should be made mandatory, as the system is able to identify laboratories with suboptimal performance that may need technical advice. Updated 2013 ASCO/CAP recommendations should be adopted as the widening of IHC 2+ "equivocal" category would improve overall accuracy of HER2 testing, as more cases would be classified in this category and, consequently, tested with an in situ hybridisation method.

PubMed Disclaimer

References

    1. J Pathol. 2001 Nov;195(4):422-8 - PubMed
    1. J Clin Pathol. 2000 Dec;53(12):890-2 - PubMed
    1. J Clin Oncol. 2008 Oct 20;26(30):4869-74 - PubMed
    1. Breast Care (Basel). 2008;3(2):128-133 - PubMed
    1. Adv Anat Pathol. 2010 Nov;17(6):404-18 - PubMed

MeSH terms

Substances