Clinical Trial
. 2015 May;147(5):1267-1274.
doi: 10.1378/chest.14-1465.

Percutaneous dilatational tracheostomy with a double-lumen endotracheal tube: a comparison of feasibility, gas exchange, and airway pressures

Affiliations
Clinical Trial

Percutaneous dilatational tracheostomy with a double-lumen endotracheal tube: a comparison of feasibility, gas exchange, and airway pressures

Maria Vargas et al. Chest. 2015 May.

Abstract

Objective: Gas exchange and airway pressures are markedly altered during percutaneous dilatational tracheostomy (PDT). A double-lumen endotracheal tube (DLET) has been developed for better airway management during PDT. The current study prospectively evaluated the in vivo feasibility, gas exchange, and airway pressures during PDT with DLET compared with a conventional endotracheal tube (ETT).

Methods: According to eligibility criteria, patients were divided into a case group (those receiving PDT with DLET) and a control group (those receiving PDT with a conventional ETT). The Ciaglia single-dilator technique was used for PDT in both groups. The primary end point of this study was the feasibility of tracheostomy with DLET. The secondary end points were a comparison of gas exchange, airway pressures, minute volume, and tidal volume before, during, and after PDT performed with DLET and conventional ETT.

Results: Ten patients meeting the inclusion criteria were assigned to each group. PDTs were performed without difficulties in nine patients in the DLET group and 10 patients in the conventional ETT group. During PDT, gas exchange, airway pressures, and minute ventilation remained more stable in the DLET group and were significantly different from those in the conventional ETT group.

Conclusions: PDT with DLET can be performed safely without difficulties limiting the technique. Furthermore, during PDT, the use of the DLET resulted in more stable gas exchange, airway pressures, and ventilation than PDT with a conventional ETT.

Trial registry: ClinicalTrials.gov; No.: NCT01691222; URL: www.clinicaltrials.gov.

PubMed Disclaimer

Comment in

Associated data