Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2015 Apr;25(4):961-9.
doi: 10.1007/s00330-014-3469-2. Epub 2014 Nov 8.

Diagnostic performance of CT-arthrography and 1.5T MR-arthrography for the assessment of glenohumeral joint cartilage: a comparative study with arthroscopic correlation

Affiliations
Comparative Study

Diagnostic performance of CT-arthrography and 1.5T MR-arthrography for the assessment of glenohumeral joint cartilage: a comparative study with arthroscopic correlation

Patrick Omoumi et al. Eur Radiol. 2015 Apr.

Abstract

Purpose: To compare the diagnostic performance of multi-detector CT arthrography (CTA) and 1.5-T MR arthrography (MRA) in detecting hyaline cartilage lesions of the shoulder, with arthroscopic correlation.

Patients and methods: CTA and MRA prospectively obtained in 56 consecutive patients following the same arthrographic procedure were independently evaluated for glenohumeral cartilage lesions (modified Outerbridge grade ≥2 and grade 4) by two musculoskeletal radiologists. The cartilage surface was divided in 18 anatomical areas. Arthroscopy was taken as the reference standard. Diagnostic performance of CTA and MRA was compared using ROC analysis. Interobserver and intraobserver agreement was determined by κ statistics.

Results: Sensitivity and specificity of CTA varied from 46.4 to 82.4 % and from 89.0 to 95.9 % respectively; sensitivity and specificity of MRA varied from 31.9 to 66.2 % and from 91.1 to 97.5 % respectively. Diagnostic performance of CTA was statistically significantly better than MRA for both readers (all p ≤ 0.04). Interobserver agreement for the evaluation of cartilage lesions was substantial with CTA (κ = 0.63) and moderate with MRA (κ = 0.54). Intraobserver agreement was almost perfect with both CTA (κ = 0.94-0.95) and MRA (κ = 0.83-0.87).

Conclusion: The diagnostic performance of CTA and MRA for the detection of glenohumeral cartilage lesions is moderate, although statistically significantly better with CTA.

Key points: • CTA has moderate diagnostic performance for detecting glenohumeral cartilage substance loss. • MRA has moderate diagnostic performance for detecting glenohumeral cartilage substance loss. • CTA is more accurate than MRA for detecting cartilage substance loss.

PubMed Disclaimer

References

    1. Diagn Interv Imaging. 2013 Apr;94(4):371-88 - PubMed
    1. AJR Am J Roentgenol. 1994 Sep;163(3):629-36 - PubMed
    1. Radiology. 2001 Jan;218(1):127-32 - PubMed
    1. Skeletal Radiol. 2010 Dec;39(12):1199-204 - PubMed
    1. Radiology. 2003 Jan;226(1):165-70 - PubMed

Publication types

LinkOut - more resources