Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 2014 Oct;70(4):371-6.
doi: 10.1016/j.mjafi.2014.04.015. Epub 2014 Aug 4.

Bearing surfaces in hip replacement - Evolution and likely future

Affiliations
Review

Bearing surfaces in hip replacement - Evolution and likely future

Narinder Kumar et al. Med J Armed Forces India. 2014 Oct.

Abstract

Total hip arthroplasty has evolved from the first total hip arthroplasty in 1938, through the revolutionization of hip arthroplasty by principles of low friction arthroplasty introduced by Sir John Charnley in 1960s to the present state of the art implants and techniques. The main concern regarding failure of total hip arthroplasty has been the biological response to particulate polyethylene debris generated by conventional metal on polyethylene bearing surfaces leading to osteolysis and aseptic loosening of the prosthesis. Therefore, recent research has been focussing on alternative bearing surfaces to reduce the particulate debris generated. These bearing surfaces include ceramic-polyethylene, metal-metal as well as ceramic-ceramic articulations and have demonstrated lesser friction rates as well as significantly lower wear rates as compared to widely used metal on polyethylene surfaces. Clinical experience until now has shown that metal on metal articulations have significant safety concerns whereas metal-on-highly crosslinked polyethylene, ceramic on ceramic and ceramic on highly crosslinked polyethylene articulations have shown encouraging results to hold promise for wider use in younger and more active patients. This review article discusses positives and drawbacks of various bearing surfaces in current clinical use in total hip arthroplasty as well as briefly explores the newer technologies on the horizon which may even further decrease wear and improve total hip arthroplasty survivorship.

Keywords: Bearing surfaces; Evolution; Total hip arthroplasty.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Metal on polyethylene – The gold standard.
Fig. 2
Fig. 2
Extensive metallosis – Revision of a metal on metal.
Fig. 3
Fig. 3
Fractured ceramic liner of acetabular component.
Fig. 4
Fig. 4
Revised fractured ceramic bearing surfaces.

References

    1. Learmonth I.D., Young C., Rorabeck C. The operation of the century: total hip replacement. Lancet. 2007 Oct 27;370(9597):1508–1519. - PubMed
    1. Coventry M.B. Foreword. In: Amutz H.C., editor. Hip Arthroplasty. Churchill Livingstone; New York: 1991.
    1. Smith Peterson M.N. The classic: evolution of mould arthroplasty of the hip joint. J Bone Joint Surg Br. 1948;30B:L59. - PubMed
    1. Wiles P. The surgery of the osteoarthritic hip. Br J Surg. 1958;45:88–97. - PubMed
    1. Sandiford N.A., Alao U., Skinner J.A., Samsani S.R. Hip arthroplasty, recent advances in hip and knee arthroplasty. In: Fokter Samo., editor. 2012. InTech, Available from: http://www.intechopen.com/books/recent-advances-in-hip-and-knee-arthropl....

LinkOut - more resources