Mold contamination in a controlled hospital environment: a 3-year surveillance in southern Italy
- PMID: 25398412
- PMCID: PMC4236478
- DOI: 10.1186/s12879-014-0595-z
Mold contamination in a controlled hospital environment: a 3-year surveillance in southern Italy
Abstract
Background: Environmental monitoring of airborne filamentous fungi is necessary to reduce fungal concentrations in operating theaters and in controlled environments, and to prevent infections. The present study reports results of a surveillance of filamentous fungi carried out on samples from air and surfaces in operating theaters and controlled environments in an Italian university hospital.
Methods: Sampling was performed between January 2010 and December 2012 in 32 operating theaters and five departments with high-risk patients. Indoor air specimens were sampled using a microbiological air sampler; Rodac contact plates were used for surface sampling. Fungal isolates were identified at the level of genera and species.
Results: Sixty-one samples (61/465; 13.1%) were positive for molds, with 18 from controlled environments (18/81; 22.2%) and 43 (43/384; 11.2%) from operating theaters. The highest air fungal load (AFL, colony-forming units per cubic meter [CFU/m(3)]) was recorded in the ophthalmology operating theater, while the pediatric onco-hematology ward had the highest AFL among the wards (47 CFU/m(3)). The most common fungi identified from culture of air specimens were Aspergillus spp. (91.8%), Penicillium spp., (6%) and Paecilomyces spp. (1.5%). During the study period, a statistically significant increase in CFU over time was recorded in air-controlled environments (p = 0.043), while the increase in AFL in operating theaters was not statistically significant (p = 0.145). Molds were found in 29.1% of samples obtained from surfaces. Aspergillus fumigatus was the most commonly isolated (68.5%).
Conclusions: Our findings will form the basis for action aimed at improving the air and surface quality of these special wards. The lack of any genetic analysis prevented any correlation of fungal environmental contamination with onset of fungal infection, an analysis that will be undertaken in a prospective study in patients admitted to the same hospital.
Similar articles
-
Fungal contamination in hospital environments.Infect Control Hosp Epidemiol. 2006 Jan;27(1):44-7. doi: 10.1086/499149. Epub 2006 Jan 6. Infect Control Hosp Epidemiol. 2006. PMID: 16418986
-
Filamentous fungi in a tertiary care hospital: environmental surveillance and susceptibility to antifungal drugs.Infect Control Hosp Epidemiol. 2007 Jan;28(1):60-7. doi: 10.1086/508832. Epub 2006 Dec 15. Infect Control Hosp Epidemiol. 2007. PMID: 17230389
-
Environmental surveillance of filamentous fungi in three tertiary care hospitals in Greece.J Hosp Infect. 2002 Nov;52(3):185-91. doi: 10.1053/jhin.2002.1298. J Hosp Infect. 2002. PMID: 12419271
-
Bacterial and fungal aerosols in indoor environment in Central and Eastern European countries.Ann Agric Environ Med. 2002;9(1):17-23. Ann Agric Environ Med. 2002. PMID: 12088392 Review.
-
Mycological Methods for Routine Air Sampling and Interpretation of Results in Operating Theaters.Diagnostics (Basel). 2024 Jan 29;14(3):288. doi: 10.3390/diagnostics14030288. Diagnostics (Basel). 2024. PMID: 38337804 Free PMC article. Review.
Cited by
-
Evaluation of Air Contamination in Orthopaedic Operating Theatres in Hospitals in Southern Italy: The IMPACT Project.Int J Environ Res Public Health. 2019 Sep 25;16(19):3581. doi: 10.3390/ijerph16193581. Int J Environ Res Public Health. 2019. PMID: 31557819 Free PMC article.
-
Capturing the Features of Physical Activity in Old Adults during the COVID-19 Pandemic: Results of an Italian Survey.Int J Environ Res Public Health. 2022 Jun 3;19(11):6868. doi: 10.3390/ijerph19116868. Int J Environ Res Public Health. 2022. PMID: 35682451 Free PMC article.
-
Severe Recurrent COVID-Associated Pulmonary Aspergillosis: A Challenging Case.Healthcare (Basel). 2022 Dec 8;10(12):2483. doi: 10.3390/healthcare10122483. Healthcare (Basel). 2022. PMID: 36554008 Free PMC article.
-
Medication Errors in Intensive Care Units: An Umbrella Review of Control Measures.Healthcare (Basel). 2022 Jun 29;10(7):1221. doi: 10.3390/healthcare10071221. Healthcare (Basel). 2022. PMID: 35885748 Free PMC article. Review.
-
Study on the relationship between the concentration and type of fungal bio-aerosols at indoor and outdoor air in the Children's Medical Center, Tehran, Iran.Environ Monit Assess. 2019 Jan 4;191(2):48. doi: 10.1007/s10661-018-7183-4. Environ Monit Assess. 2019. PMID: 30610385
References
-
- Sehulster L, Chinn RY. Guidelines for environmental infection control in health-care facilities. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee (HICPAC) MMWR Recomm Rep. 2003;52:1–42. - PubMed
-
- Safe Surgery Saves Lives. 2009, World Health Organization, Geneva - PubMed
-
- Hao ZF, Ao JH, Hao F, Yanf RY, Zhu H, Zhang J. Environment surveillance of filamentous fungi in two tertiary care hospitals in China. Chin Med J. 2011;124:1970–1975. - PubMed
-
- Montagna MT, Lovero G, Coretti C, Martinelli D, Delia M, De Giglio O, Caira M, Puntillo F, D'Antonio D, Venditti M, Sambri V, Di Bernardo F, Barbui A, Lo Cascio G, Concia E, Mikulska M, Viscoli C, Maximova N, Candoni A, Oliveri S, Lombardi G, Pitzurra L, Sanguinetti M, Masciari R, Santantonio T, Andreoni S, Barchiesi F, Pecile P, Farina C, Viale P, et al. SIMIFF study: Italian fungal registry of mold infections in hematological and non-hematological patients. Infection. 2014;42:141–151. doi: 10.1007/s15010-013-0539-3. - DOI - PMC - PubMed