. 2014 Nov 27;515(7528):540-4.
doi: 10.1038/nature13883.

Passive radiative cooling below ambient air temperature under direct sunlight

Affiliations

Passive radiative cooling below ambient air temperature under direct sunlight

Aaswath P Raman et al. Nature. .

Abstract

Cooling is a significant end-use of energy globally and a major driver of peak electricity demand. Air conditioning, for example, accounts for nearly fifteen per cent of the primary energy used by buildings in the United States. A passive cooling strategy that cools without any electricity input could therefore have a significant impact on global energy consumption. To achieve cooling one needs to be able to reach and maintain a temperature below that of the ambient air. At night, passive cooling below ambient air temperature has been demonstrated using a technique known as radiative cooling, in which a device exposed to the sky is used to radiate heat to outer space through a transparency window in the atmosphere between 8 and 13 micrometres. Peak cooling demand, however, occurs during the daytime. Daytime radiative cooling to a temperature below ambient of a surface under direct sunlight has not been achieved because sky access during the day results in heating of the radiative cooler by the Sun. Here, we experimentally demonstrate radiative cooling to nearly 5 degrees Celsius below the ambient air temperature under direct sunlight. Using a thermal photonic approach, we introduce an integrated photonic solar reflector and thermal emitter consisting of seven layers of HfO2 and SiO2 that reflects 97 per cent of incident sunlight while emitting strongly and selectively in the atmospheric transparency window. When exposed to direct sunlight exceeding 850 watts per square metre on a rooftop, the photonic radiative cooler cools to 4.9 degrees Celsius below ambient air temperature, and has a cooling power of 40.1 watts per square metre at ambient air temperature. These results demonstrate that a tailored, photonic approach can fundamentally enable new technological possibilities for energy efficiency. Further, the cold darkness of the Universe can be used as a renewable thermodynamic resource, even during the hottest hours of the day.

PubMed Disclaimer

References

    1. Appl Opt. 1996 Oct 1;35(28):5493-508 - PubMed
    1. Opt Express. 2009 Aug 17;17(17):15145-59 - PubMed
    1. Phys Rev Lett. 2004 Nov 19;93(21):213905 - PubMed
    1. Appl Opt. 1984 Feb 1;23(3):370 - PubMed
    1. Nano Lett. 2010 Feb 10;10(2):373-9 - PubMed

Publication types