Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Jul;125(7):1733-6.
doi: 10.1002/lary.25061. Epub 2014 Nov 28.

Impact of mandibular advancement devices on C-reactive protein levels in patients with obstructive sleep apnea

Affiliations

Impact of mandibular advancement devices on C-reactive protein levels in patients with obstructive sleep apnea

Sreeya Yalamanchali et al. Laryngoscope. 2015 Jul.

Abstract

Objectives/hypothesis: To determine the effect of treatment of obstructive sleep apnea (OSA) with custom-made mandibular advancement devices (MADs) on C-reactive protein (CRP) levels in patients with obstructive sleep apnea/hypopnea syndrome (OSAHS).

Study design: Case series with chart review.

Methods: Charts of consecutive patients fitted with custom-made mandibular advancement devices for treatment of OSAHS between December 2011 and November 2012 were reviewed. Demographics such as age, sex, and body mass index (BMI) were collected. Prefitting and postfitting polysomnograms were reviewed. Pre- and posttreatment apnea-hypopnea index (AHI) and average O2 saturation were compared. Only patients with documented CRP levels determined prior to mandibular advancement device fitting and again after improvement of OSAHS symptoms were included.

Results: Forty-nine patients (77.6% male, age 47.4 ± 11.7 years, BMI 29.6 ± 5.0 kg/m(2)) were included in this study. Patients initially had elevated CRP levels (2.5 ± 1.8 mg/dl), which decreased significantly following use of their custom-made mandibular advancement device (1.9 ± 1.3 mg/dl, P = 0.006) by approximately 24%. AHI decreased significantly from 33.3 ± 21.7 pretreatment to 12.1 ± 22.3 posttreatment (P < 0.001). Treatment with MADs reduced AHI by approximately 69.3%. Minimum oxygen saturation significantly improved from 85.1% ± 5.9 pretreatment to 90.7% ± 3.6 posttreatment (P < 0.001).

Conclusion: Treatment with custom-made mandibular advancement devices significantly reduced elevated CRP levels in patients with mild to severe OSAHS. Therapy achieves reasonable response and cure rates in the observed patients with a significant reduction in AHI.

Keywords: C-reactive protein; Oral appliances; mandibular advancement devices; obstructive sleep apnea.

PubMed Disclaimer

LinkOut - more resources