Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Dec;40(12):2794-804.
doi: 10.1016/j.ultrasmedbio.2014.06.015.

Differential diagnosis of gallbladder wall thickening: the usefulness of contrast-enhanced ultrasound

Affiliations
Comparative Study

Differential diagnosis of gallbladder wall thickening: the usefulness of contrast-enhanced ultrasound

Jun-Mei Xu et al. Ultrasound Med Biol. 2014 Dec.

Abstract

he purpose of this study was to evaluate the usefulness of contrast-enhanced ultrasound (CEUS) in the differential diagnosis of gallbladder wall (GBW) thickening and determine the predictors of malignant GBW thickening. One hundred fifty-nine patients with GBW thickening, including 76 men and 83 women, from eight institutions were enrolled. CEUS was performed after injection of a sulfur hexafluoride microbubble-based ultrasound contrast agent. Multiple logistic regression analysis was used to reveal independent predictor sassociated with malignant GBW thickening. The final diagnoses were 48 gallbladder carcinomas and 111 benign gallbladder diseases.Maximal thicknesses of the GBW in malignant and benign GB Wthickening were 17.3 ± 5.2 (6 – 30) mm and 8.6 ± 5.1 (4 – 26) mm respectively (p , 0.001). CEUS revealed significant differences in intralesional vessels, enhancement homogeneity, time to hypo-enhancement, inner layer discontinuity, outer layer discontinuity and adjacent liver involvement (all p-values , 0.05) between malignant and benign GBW thickening. Patient age . 46.5 y, focal GBW thickening, inner layer discontinuity and outer layer discontinuity were found to be associated with malignancy by multiple logistic regression analysis (all p-values , 0.05). Receiver operating characteristic curve analysis revealed Az values for patient age, focal GBW thickening, inner wall discontinuity and outer wall discontinuity of 0.709 (95%confidence interval [CI]: 0.627–0.790), 0.714 (95% CI: 0.630–0.798), 0.860 (95%CI: 0.791 – 0.928) and 0.858 (95% CI: 0.783 – 0.933), respectively. CEUS is useful in the differential diagnosis between malignant and benign GBW thickening. Focal GBW thickening, inner wall discontinuity and outer wall discontinuity observed on CEUS are diagnostic clues for malignant GBW thickening.

PubMed Disclaimer

Publication types

LinkOut - more resources