Observational Study
. 2014 Nov;67(11):898-905.
doi: 10.1016/j.rec.2014.01.028. Epub 2014 Jun 18.

Usefulness of 64-detector computed tomography in the diagnosis and management of patients with congenital heart disease

Affiliations
Observational Study

Usefulness of 64-detector computed tomography in the diagnosis and management of patients with congenital heart disease

Montserrat Bret-Zurita et al. Rev Esp Cardiol (Engl Ed). 2014 Nov.

Abstract

Introduction and objectives: Although congenital heart defects are the most common major congenital abnormalities, the associated mortality has been decreasing due to improvements in their diagnosis and treatment. We assessed the usefulness of 64-multidetector computed tomography in the diagnosis and management of these patients.

Methods: This 5-year observational, analytical, retrospective, cohort study included a total of 222 tomographic studies of patients with congenital heart disease. Computed tomography scans were read twice and medical records were reviewed. We assessed the complexity of the disease, patient, and radiological technique, and evaluated the contribution of new data in relation to clinical suspicion and diagnostic change. A confidence interval was set at 95% and a P value of<.05 was used as the cutoff for statistical significance.

Results: In 35.1% of patients, the treatment procedure was performed after computed tomography without other tests. Additional diagnostic catheterization was performed in 12.5% of patients. There were new findings in 77% of patients (82.9% with complex disease), which prompted a change in patient management in 35.6%. All unexpected reports described new findings. No significant differences were found by age, sex, study period, urgency of the test order, patient complexity, or difficulty of the technique.

Conclusions: Use of 64-detector computed tomography yields good diagnostic performance in congenital heart disease, prompts changes in management in more than one-third of patients, and reveals new findings in relation to the presumed diagnosis in 77% of patients.

Keywords: Cardiopatías congénitas; Congenital cardiovascular disease; Congenital heart disease; Enfermedad cardiovascular congénita; Impact; Impacto; Multidetector computed tomography; Tomografía computarizada multidetectores.