Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2014 Nov;84(5):1168-71.
doi: 10.1016/j.urology.2014.06.050. Epub 2014 Oct 24.

Histoscanning has low sensitivity and specificity for seminal vesicle invasion

Affiliations

Histoscanning has low sensitivity and specificity for seminal vesicle invasion

Jonas Schiffmann et al. Urology. 2014 Nov.

Abstract

Objective: To examine the accuracy of HistoScanning (HS) in detecting seminal vesicle (SV) invasion (SVI) within prostate cancer (PCa) patients.

Methods: We relied on our prospective institutional database. Patients who received HS before radical prostatectomy were included in the study cohort. An experienced HS examiner retrospectively reanalyzed the HS data blinded to patient characteristics and pathologic results. The HS results for every single SV were compared with the corresponding findings from the final pathologic report after radical prostatectomy. An area under the receiver operating characteristic curve for the prediction of SVI by HS was calculated. Depending on HS signal volume cut-offs (>0, >0.2, and >0.5 mL), the sensitivity, specificity, positive predictive value, and negative predictive value for the prediction of SVI were assessed.

Results: Overall, 131 patients and 262 SVs were assessable. Of those, 23 (17.5%) men had SVI, and 39 (14.9%) single SVs were infiltrated by tumor overall. The area under the receiver operating characteristic curve for predicting SVI by HS was 0.54. Depending on the HS signal volume cut-offs (>0, >0.2, and >0.5 mL), the sensitivity, specificity, positive predictive value, and negative predictive value for predicting SVI were 76.9%, 10.8%, 13.1%, and 72.7%; 61.5%, 24.2%, 12.4%, and 78.3%; and 46.2%, 50.2%, 14.0%, and 84.2%, respectively.

Conclusion: HS results did not allow a reliable prediction of SVI within PCa patients. Despite, the application of HS signal volume cut-offs (>0.2 and >0.5 mL), the prediction of SVI within PCa patients remained insufficient.

PubMed Disclaimer

Comment in

  • Editorial comment.
    Pavlovich C. Pavlovich C. Urology. 2014 Nov;84(5):1177-8. doi: 10.1016/j.urology.2014.05.074. Epub 2014 Oct 24. Urology. 2014. PMID: 25443927 No abstract available.

LinkOut - more resources