Observational Study
. 2015 Feb;12(2):360-6.
doi: 10.1016/j.hrthm.2014.10.034. Epub 2014 Oct 30.

Clinical and serum-based markers are associated with death within 1 year of de novo implant in primary prevention ICD recipients

Affiliations
Observational Study

Clinical and serum-based markers are associated with death within 1 year of de novo implant in primary prevention ICD recipients

Yiyi Zhang et al. Heart Rhythm. 2015 Feb.

Abstract

Background: Implantable cardioverter-defibrillator (ICD) implantation is contraindicated in those with <1-year life expectancy.

Objectives: The aim of this study was to develop a risk prediction score for 1-year mortality in patients with primary prevention ICDs and to determine the incremental improvement in discrimination when serum-based biomarkers are added to traditional clinical variables.

Methods: We analyzed data from the Prospective Observational Study of Implantable Cardioverter-Defibrillators, a large prospective observational study of patients undergoing primary prevention ICD implantation who were extensively phenotyped for clinical and serum-based biomarkers. We identified variables predicting 1-year mortality and synthesized them into a comprehensive risk scoring construct using backward selection.

Results: Of 1189 patients deemed by their treating physicians as having a reasonable 1-year life expectancy, 62 (5.2%) patients died within 1 year of ICD implantation. The risk score, composed of 6 clinical factors (age ≥75 years, New York Heart Association class III/IV, atrial fibrillation, estimated glomerular filtration rate <30 mL/min/1.73 m(2), diabetes, and use of diuretics), had good discrimination (area under the curve 0.77) for 1-year mortality. Addition of 3 biomarkers (tumor necrosis factor α receptor II, pro-brain natriuretic peptide, and cardiac troponin T) further improved model discrimination to 0.82. Patients with 0-1, 2-3, 4-6, or 7-9 risk factors had 1-year mortality rates of 0.8%, 2.7%, 16.1%, and 46.2%, respectively.

Conclusion: Individuals with more comorbidities and elevation of specific serum biomarkers were at increased risk of all-cause mortality despite being deemed as having a reasonable 1-year life expectancy. A simple risk score composed of readily available clinical data and serum biomarkers may better identify patients at high risk of early mortality and improve patient selection and counseling for primary prevention ICD therapy.

Keywords: Early mortality; ICD shock; Implantable cardioverter-defibrillator; Primary prevention; Sudden cardiac death.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Distribution of the clinical and biomarker risk score (A), and the Kaplan-Meier survival curves by risk score categories (B).

References

    1. Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, Daubert JP, Higgins SL, Brown MW, Andrews ML. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002 Mar 21;346:877–883. - PubMed
    1. Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005 Jan 20;352:225–237. - PubMed
    1. Buxton AE, Lee KL, Fisher JD, Josephson ME, Prystowsky EN, Hafley G. A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators. N Engl J Med. 1999 Dec 16;341:1882–1890. - PubMed
    1. Kadish A, Dyer A, Daubert JP, et al. Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy. N Engl J Med. 2004 May 20;350:2151–2158. - PubMed
    1. Epstein AE, DiMarco JP, Ellenbogen KA, et al. ACC/AHA/HRS 2008 Guidelines for Device-Based Therapy of Cardiac Rhythm Abnormalities: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Writing Committee to Revise the ACC/AHA/NASPE 2002 Guideline Update for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices): developed in collaboration with the American Association for Thoracic Surgery and Society of Thoracic Surgeons. Circulation. 2008 May 27;117:e350–408. - PubMed

Publication types

MeSH terms