Functional outcome after resuscitative endovascular balloon occlusion of the aorta of the proximal and distal thoracic aorta in a swine model of controlled hemorrhage
- PMID: 25449984
- DOI: 10.1016/j.avsg.2014.10.004
Functional outcome after resuscitative endovascular balloon occlusion of the aorta of the proximal and distal thoracic aorta in a swine model of controlled hemorrhage
Abstract
Background: Noncompressible torso hemorrhage remains an ongoing problem for both military and civilian trauma. Resuscitative endovascular balloon occlusion of the aorta (REBOA) has been characterized as a potentially life-saving maneuver. The objective of this study was to determine the functional outcomes, paraplegia rates, and survival of 60-min balloon occlusion in the proximal and distal thoracic aorta in a porcine model of controlled hemorrhage.
Methods: Swine (Sus scrofa, 70-110 kg) were subjected to class IV hemorrhagic shock and underwent 60 min of REBOA. Devices were introduced from the left carotid artery and positioned in the thoracic aorta in either the proximal location (pREBOA [n = 8]; just past takeoff of left subclavian artery) or distal location (dREBOA [n = 8]; just above diaphragm). After REBOA, animals were resuscitated with whole blood, crystalloid, and vasopressors before a 4-day postoperative period. End points included evidence of spinal cord ischemia (clinical examination, Tarlov gait score, bowel and bladder dysfunction, and histopathology), gross ischemia-reperfusion injury (clinical examination and histopathology), and mortality.
Results: The overall mortality was similar between pREBOA and dREBOA groups at 37.5% (n = 3). Spinal cord-related mortality was 12.5% for both pREBOA and dREBOA groups. Spinal cord symptoms without death were present in 12.5% of pREBOA and dREBOA groups. Average gait scores improved throughout the postoperative period.
Conclusions: REBOA placement in the proximal or distal thoracic aorta does not alter mortality or paraplegia rates as compared with controlled hemorrhage alone. Functional recovery improves in the presence or the absence of REBOA, although at a slower rate after REBOA as compared with negative controls. Additional research is required to determine the ideal placement of REBOA in an uncontrolled hemorrhage model to achieve use compatible with survival outcomes and quality of life.
Copyright © 2015 Elsevier Inc. All rights reserved.
Similar articles
-
Physiologic tolerance of descending thoracic aortic balloon occlusion in a swine model of hemorrhagic shock.Surgery. 2013 Jun;153(6):848-56. doi: 10.1016/j.surg.2012.12.001. Epub 2013 Feb 27. Surgery. 2013. PMID: 23453327
-
The inflammatory sequelae of aortic balloon occlusion in hemorrhagic shock.J Surg Res. 2014 Oct;191(2):423-31. doi: 10.1016/j.jss.2014.04.012. Epub 2014 Apr 13. J Surg Res. 2014. PMID: 24836421
-
Endovascular variable aortic control (EVAC) versus resuscitative endovascular balloon occlusion of the aorta (REBOA) in a swine model of hemorrhage and ischemia reperfusion injury.J Trauma Acute Care Surg. 2018 Sep;85(3):519-526. doi: 10.1097/TA.0000000000002008. J Trauma Acute Care Surg. 2018. PMID: 30142105
-
Large Animal Models of Proximal Aortic Balloon Occlusion in Traumatic Hemorrhage: Review and Identification of Knowledge Gaps Relevant to Expanded Use.J Surg Res. 2019 Apr;236:247-258. doi: 10.1016/j.jss.2018.11.038. Epub 2018 Dec 21. J Surg Res. 2019. PMID: 30694763 Review.
-
Resuscitative Endovascular Balloon Occlusion of the Aorta for Hemorrhage Control in Trauma Patients: An Evidence-Based Review.J Trauma Nurs. 2018 Jan/Feb;25(1):33-37. doi: 10.1097/JTN.0000000000000339. J Trauma Nurs. 2018. PMID: 29319648 Review.
Cited by
-
A randomized porcine study of hemorrhagic shock comparing end-tidal carbon dioxide targeted and proximal systolic blood pressure targeted partial resuscitative endovascular balloon occlusion of the aorta in the mitigation of metabolic injury.Intensive Care Med Exp. 2023 Apr 10;11(1):18. doi: 10.1186/s40635-023-00502-w. Intensive Care Med Exp. 2023. PMID: 37032421 Free PMC article.
-
A self calibrating, magnetic sensor approach accurately positions an aortic damage control stent in a porcine model.Trauma Surg Acute Care Open. 2023 Dec 8;8(1):e001220. doi: 10.1136/tsaco-2023-001220. eCollection 2023. Trauma Surg Acute Care Open. 2023. PMID: 38089400 Free PMC article.
-
A three-tier Rescue stent improves outcomes over balloon occlusion in a porcine model of noncompressible hemorrhage.J Trauma Acute Care Surg. 2020 Aug;89(2):320-328. doi: 10.1097/TA.0000000000002715. J Trauma Acute Care Surg. 2020. PMID: 32740640 Free PMC article.
-
Damage control approach to refractory neurogenic shock: a new proposal to a well-established algorithm.Colomb Med (Cali). 2021 Jun 30;52(2):e4164800. doi: 10.25100/cm.v52i2.4800. eCollection 2021 Apr-Jun. Colomb Med (Cali). 2021. PMID: 34908624 Free PMC article. Review.
-
Prehospital control of life-threatening truncal and junctional haemorrhage is the ultimate challenge in optimizing trauma care; a review of treatment options and their applicability in the civilian trauma setting.Scand J Trauma Resusc Emerg Med. 2016 Sep 13;24(1):110. doi: 10.1186/s13049-016-0301-9. Scand J Trauma Resusc Emerg Med. 2016. PMID: 27623805 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous