. 2014 Dec;100(8):891-4.
doi: 10.1016/j.otsr.2014.07.021. Epub 2014 Nov 14.

Vascular injuries during closing-wedge high tibial osteotomy: A cadaveric angiographic study

Affiliations
Free article

Vascular injuries during closing-wedge high tibial osteotomy: A cadaveric angiographic study

A Darnis et al. Orthop Traumatol Surg Res. 2014 Dec.
Free article

Abstract

Introduction: Closing-wedge high tibial osteotomy is a surgical option for patients with isolated medial compartment osteoarthritis and varus knee alignment. Vascular complications are rare, but incriminate the use of oscillating saw or osteotome. It is important to know the steps of this surgery that involve risk of vascular injury and what to do to decrease that risk.

Hypothesis: Performing the distal osteotomy cut using an oscillating saw is a step with high risk of vascular injury. A protective device behind the tibia may decrease this risk.

Materials and methods: In this descriptive angiographic cadaver study, closing-wedge high tibial osteotomy was performed on 6 cadaveric knees in 90° knee flexion, and the distance between the surgical instrument and the popliteal artery was measured on fluoroscopy with artery opacification at the various steps of surgery.

Results: Tibial osteotomy with oscillating saw involves high vascular risk: the mean distance between the saw-blade and the popliteal artery is 10.6mm in 90° knee flexion. Using a specific device placed behind the tibia protects the vascular structures.

Discussion: High tibial osteotomy is indicated in medial compartment osteoarthritis of the knee and can be performed by closing or opening-wedge. Vascular injuries in closing-wedge osteotomy exist and it is recommended to perform this surgery at 90° knee flexion, although some studies report that this does not move the artery out of the way. A risk of vascular lesion should be kept in mind. The oscillation of the saw and the direction of the osteotomy should also be taken into consideration when performing a closing-wedge high tibial osteotomy in order to protect the popliteal artery.

Study design: Descriptive cadaver study. Level IV.

Keywords: Anatomical study; Closing-wedge; High tibial osteotomy; Popliteal artery; Vascular injury.