Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2014 Dec 5:1371:30-8.
doi: 10.1016/j.chroma.2014.10.062. Epub 2014 Oct 30.

Microextraction by packed sorbent coupled with gas chromatography-mass spectrometry: a comparison between "draw-eject" and "extract-discard" methods under equilibrium conditions for the determination of polycyclic aromatic hydrocarbons in water

Affiliations
Comparative Study

Microextraction by packed sorbent coupled with gas chromatography-mass spectrometry: a comparison between "draw-eject" and "extract-discard" methods under equilibrium conditions for the determination of polycyclic aromatic hydrocarbons in water

Maurizio Quinto et al. J Chromatogr A. .

Abstract

In this work, two different extraction procedures for the analysis of different polycyclic aromatic hydrocarbons (PAHs) in water by microextraction by packed sorbent (MEPS) have been compared in terms of sensitivity, reliability and time of analysis. The first method, called "draw-eject", consists of a sequence of cycles of aspirations and injections in the same vial; the second one, called "extract-discard", consists of a similar cycle sequence, but the aspired sample in this case is discarded into waste. The relevant partition equilibriums and extraction rates have been calculated by multivariate regression from the data obtained after MEPS gas chromatography-mass spectrometry (MEPS-GC-MS) analysis of 16 PAHs from water samples. Partitioning parameters for a priori prediction of solute sorption equilibrium, recoveries and preconcentration effects in aqueous and solvent systems have been calculated and compared for the two extraction procedures. Finally, real samples from sea, agricultural irrigation wells, streams and tap water were analyzed. Detection (S/N≥3) and quantification (S/N≥10) limits were calculated for the extraction processes. Under the experimental conditions used for the "draw-eject" procedure, these values were in the range 0.5-2 ng L(-1) and 1.6-6.2 ng L(-1), while for the "extract-discard" procedure they ranged from 0.2 to 0.8 ng L(-1) and from 0.8 to 2.0 ng L(-1), respectively.

Keywords: Gas chromatography; Mass spectrometry; Mathematical model; Microextraction by packed sorbent; Polycyclic aromatic hydrocarbons; Water analysis.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources