Histopathological heterogeneity of in-stent restenosis in four coronary endarterectomy specimens
- PMID: 25483741
- DOI: 10.1016/j.carpath.2014.11.002
Histopathological heterogeneity of in-stent restenosis in four coronary endarterectomy specimens
Abstract
Here, we histopathologically compare four patients undergoing coronary artery bypass with coronary endarterectomy and onlay patch grafting for in-stent restenosis (ISR) after the implantation of a bare-metal stent (BMS), sirolimus-eluting stent (SES), or paclitaxel-eluting stent (PES) in an everolimus-eluting stent (EES). Heterogeneity of ISR was noted histopathologically. In ISR for BMS, restenosis is likely caused by so-called neoatherosclerosis that occurred which altered the healing process of BMS implantation. Two ISR cases for SES showed a histopathological heterogeneity: one showed nodular calcified thrombus around stent strut protruding into the lumen, and the other showed concentric neointima composed of CD68-positive foam cell proliferation. In the ISR lesion for PES in EES, infiltrations with foam cells macrophages, particularly numerous eosinophilic cell infiltrations, suggest a peristent strut hypersensitivity reaction. We found a remarkable histopathological heterogeneity of ISR. The study using coronary endarterectomy specimens can give us pivotal information about the histopathological heterogeneity of ISR.
Keywords: Coronary artery bypass; Coronary endarterectomy; In-stent restenosis; Percutaneous coronary intervention.
Copyright © 2014 Elsevier Inc. All rights reserved.