. 2014;10(4):231-7.
doi: 10.5114/pwki.2014.46763. Epub 2014 Nov 17.

Feasibility of virtual 3-Fr percutaneous coronary intervention using standard guiding catheters

Affiliations

Feasibility of virtual 3-Fr percutaneous coronary intervention using standard guiding catheters

Tsuyoshi Honda et al. Postepy Kardiol Interwencyjnej. 2014.

Abstract

Introduction: Recent studies have reported the efficacy of sheathless percutaneous coronary intervention (PCI) using hydrophilic-coated 5-Fr guiding catheters that are one to two Fr sizes smaller in diameter than the corresponding introducer sheath (virtual 3-Fr PCI). However, the limited number of shapes of hydrophilic-coated guiding catheters occasionally makes them difficult to engage and control.

Aim: To evaluate the efficacy and feasibility of virtual 3-Fr PCI using standard guiding catheters of various shapes.

Material and methods: We identified 35 consecutive patients with stable angina, who underwent virtual 3-Fr PCI using either hydrophilic-coated guiding catheters (Works™, Medikit, Japan) or standard guiding catheters (Heartrail™, Terumo, Japan).

Results: Thirty-five patients were identified (63% men; mean age 70 ±13 years). In 2 cases, hydrophilic-coated guiding catheters were exchanged to standard guiding catheters because of difficulty in engaging the target coronary arteries. Ultimately, standard guiding catheters were used in 20 patients (57%) and hydrophilic-coated catheters were used in 15 (43%). One of 20 patients treated with standard guiding catheters and 1 of 15 treated with hydrophilic-coated guiding catheters underwent the 4-in-3 "slender mother and child" PCI technique due to difficulty of stent deployment. There were no differences between the two groups in PCI procedural variables such as procedural time, fluoroscopy time, radiation dose, or contrast dye volume. There were no access site-related complications in this study.

Conclusions: These findings indicate that virtual 3-Fr PCI using standard guiding catheters is as efficient and safe as virtual 3-Fr PCI using hydrophilic-coated guiding catheters.

Keywords: virtual 3-Fr percutaneous coronary intervention.

PubMed Disclaimer

Figures

Figure 1
Figure 1
A colour photograph of the 4-Fr dilators and 5-Fr guiding catheters. A – A 5-Fr hydrophilic-coated guiding catheter and the additional 4-Fr dilator (Works™). B – The 4-Fr dilator is deeply inserted into the 5-Fr hydrophilic-coated guiding catheter (Works™). C, D – An optional 4-Fr dilator is deeply inserted into a 5-Fr standard guiding catheter (Heartrail™). E – A 5-Fr standard guiding catheter (Heartrail™) and a 4-Fr conventional sheath. F – A haemostatic device (TOMETA KUNTM) GC – guiding catheter, GW – guide wire

Similar articles

Cited by

References

    1. Grüntzig A, Schneider HJ. The percutaneous dilatation of chronic coronary stenosis – experiments and morphology. Schweiz Med Wochenschr. 1977;107:1588. - PubMed
    1. Kiemeneij F, Laarmann GJ, Odekerken D, et al. A randomized comparison of percutaneous transluminal coronary angioplasty by the radial, brachial and femoral approaches: the access study. J Am Coll Cardiol. 1997;29:1269–75. - PubMed
    1. Ikari Y, Matsukage T, Yoshimachi F. Coronary intervention: less invasive strategy in PCI. Cardiovasc Interv Ther. 2012;27:84–92. - PubMed
    1. Honda T, Fujimoto K, Miyao Y, et al. Access site-related complications after transradial catheterization reduced with smaller sheath size and statins. Cardiovasc Interv Ther. 2012;27:174–80. - PubMed
    1. Takeshita S, Saito S. Transradial coronary intervention using a novel 5-Fr sheathless guiding catheter. Catheter Cardiovasc Interv. 2009;74:862–5. - PubMed

LinkOut - more resources