Oscillometric blood pressure: a review for clinicians
- PMID: 25492837
- DOI: 10.1016/j.jash.2014.08.014
Oscillometric blood pressure: a review for clinicians
Abstract
Oscillometric devices for the non-invasive estimation of blood pressure (BP) have become the "clinical standard" because of training requirements for determination of BP by auscultation, cost, and the phasing-out/banning of mercury in many states and countries. Analysis of recent publications reveals a lack of understanding of the "meaning" of oscillometric blood pressure (OBP) measurements by authors, journal editors, and clinicians. We were invited to submit a review of OBP methodology written for clinicians. We hope that the material contained herein will clarify how clinicians should interpret OBP values for their patients.
Keywords: Diastolic blood pressure; mean blood pressure; oscillometric blood pressure measurement; oscillometry; systolic blood pressure.
Copyright © 2014 American Society of Hypertension. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Automatic blood pressure measurement: the oscillometric waveform shape is a potential contributor to differences between oscillometric and auscultatory pressure measurements.J Hypertens. 2008 Jan;26(1):35-43. doi: 10.1097/HJH.0b013e3282f06ec7. J Hypertens. 2008. PMID: 18090538
-
Auscultatory versus oscillometric measurement of blood pressure in octogenarians.Blood Press. 2012 Oct;21(5):269-72. doi: 10.3109/08037051.2012.680751. Epub 2012 May 1. Blood Press. 2012. PMID: 22545576
-
Comparison of automated oscillometric versus auscultatory blood pressure measurement.Am J Cardiol. 2010 Aug 1;106(3):386-8. doi: 10.1016/j.amjcard.2010.03.040. Epub 2010 May 22. Am J Cardiol. 2010. PMID: 20643251
-
Home blood pressure measurement with oscillometric upper-arm devices.Neth J Med. 2003 Oct;61(10):307-12. Neth J Med. 2003. PMID: 14708907 Review.
-
From Korotkoff and Marey to automatic non-invasive oscillometric blood pressure measurement: does easiness come with reliability?Expert Rev Med Devices. 2016;13(2):179-89. doi: 10.1586/17434440.2016.1128821. Epub 2016 Jan 8. Expert Rev Med Devices. 2016. PMID: 26641026 Review.
Cited by
-
Blood pressure measurements with the OptiBP smartphone app validated against reference auscultatory measurements.Sci Rep. 2020 Oct 20;10(1):17827. doi: 10.1038/s41598-020-74955-4. Sci Rep. 2020. PMID: 33082436 Free PMC article.
-
Accuracy of cuff blood pressure and systolic blood pressure amplification.Hypertens Res. 2023 Aug;46(8):1961-1969. doi: 10.1038/s41440-023-01311-0. Epub 2023 May 22. Hypertens Res. 2023. PMID: 37217732 Free PMC article.
-
Systolic peak foot-to-apex time interval, a novel oscillometric technique for systolic blood pressure measurement.J Hypertens. 2017 May;35(5):1002-1010. doi: 10.1097/HJH.0000000000001252. J Hypertens. 2017. PMID: 28099195 Free PMC article.
-
Endothelial Function Assessed by Automatic Measurement of Enclosed Zone Flow-Mediated Vasodilation Using an Oscillometric Method Is an Independent Predictor of Cardiovascular Events.J Am Heart Assoc. 2016 Dec 21;5(12):e004385. doi: 10.1161/JAHA.116.004385. J Am Heart Assoc. 2016. PMID: 28003249 Free PMC article.
-
Blood pressure measurement using only a smartphone.NPJ Digit Med. 2022 Jul 6;5(1):86. doi: 10.1038/s41746-022-00629-2. NPJ Digit Med. 2022. PMID: 35794240 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources