Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2015 May;27(4):465-470.
doi: 10.1111/den.12415. Epub 2015 Jan 19.

Magnetic endoscope imaging in single-balloon enteroscopy

Affiliations
Clinical Trial

Magnetic endoscope imaging in single-balloon enteroscopy

Christoph Schlag et al. Dig Endosc. 2015 May.

Abstract

Background and aim: Magnetic endoscope imaging (MEI) provides continuous viewing of the position of the endoscope on a monitor without using X-ray and has already been established for colonoscopy. The aim of the present study was to evaluate a new MEI probe for enteroscopy.

Methods: In this prospective feasibility study, consecutive patients received single-balloon enteroscopy guided by the new MEI probe. Fluoroscopy was also used in all examinations. MEI images were compared to fluoroscopy images with respect to concordance of loop configuration by two independent observers after the examinations. Main outcome measurement was the rate of concordant MEI and fluoroscopy images with respect to loop configuration.

Results: In all 10 patients, single-balloon enteroscopy with MEI was carried out without any adverse events or technical difficulties. Concordance of MEI and fluoroscopy images was seen in 36/38 images (95%; 95% CI, 82-99%) by both observers. Overall agreement between the two observers was 95% (κ = 0.47, 95% CI, -0.04-1).

Conclusion: The use of MEI in single-balloon enteroscopy is safe and feasible. Detection and control of loops can be accurately achieved.

Keywords: balloon endoscopy; enteroscopy; fluoroscopy; magnetic endoscope imaging; small bowel.

PubMed Disclaimer

References

    1. Bladen JS, Anderson AP, Bell GD, Rameh B, Evans B, Heatley DJ. Non-radiological technique for three-dimensional imaging of endoscopes. Lancet 1993; 341: 719-722.
    1. Saunders BP, Bell GD, Williams CB, Bladen JS, Anderson AP. First clinical results with a real time, electronic imager as an aid to colonoscopy. Gut 1995; 36: 913-917.
    1. Shah SG, Saunders BP, Brooker JC, Williams CB. Magnetic imaging of colonoscopy: An audit of looping, accuracy and ancillary maneuvers. Gastrointest. Endosc. 2000; 52: 1-8.
    1. Shah SG, Brooker JC, Williams CB, Thapar C, Saunders BP. Effect of magnetic endoscope imaging on colonoscopy performance: A randomised controlled trial. Lancet 2000; 356: 1718-1722.
    1. Hoff G, Bretthauer M, Dahler S et al. Improvement in caecal intubation rate and pain reduction by using 3-dimensional magnetic imaging for unsedated colonoscopy: A randomized trial of patients referred for colonoscopy. Scand. J. Gastroenterol. 2007; 42: 885-889.

Publication types

MeSH terms

LinkOut - more resources