Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2015 Feb;193(1):47-51.
doi: 10.1007/s00408-014-9674-6. Epub 2014 Dec 17.

Assessment of spirometry and impulse oscillometry in relation to asthma control

Affiliations
Comparative Study

Assessment of spirometry and impulse oscillometry in relation to asthma control

Arvind Manoharan et al. Lung. 2015 Feb.

Abstract

Introduction: Guidelines advocate the use of spirometry to assess pulmonary function in asthmatic patients. Commonly used measures include forced expiratory volume in 1 s (FEV1), forced expiratory ratio (FEV1/FVC), and forced mid-expiratory flow between 25 and 75 % of forced vital capacity (FEF25-75). Impulse oscillometry (IOS) is an effort-independent test performed during tidal breathing. IOS may be used to assess the total and central airway resistance at 5 Hz (R5) and 20 Hz (R20), respectively, and hence derive the peripheral airway resistance from the difference (R5-R20). We compared spirometry and IOS as tests of global airway function (i.e., FEV1, FEV1/FVC, R5) and putative measures of small airways function (i.e., FEF25-75, R5-R20) and their relationship to oral steroid and short-acting beta-agonist (SABA) use as surrogates for long-term asthma control.

Methods: Spirometry and IOS measurements from physician-diagnosed asthmatics were linked to a health informatics database for oral steroid and SABA use 1 year prior to the index measurements.

Results: Four hundred forty-two patients had both spirometry and IOS, mean FEV1 = 86 % predicted, 94 % on ICS, median dose 800 µg/day. IOS and spirometry measures were equally predictive of impaired asthma control for both oral steroid and SABA use. For oral steroid use, the adjusted odds ratio, OR (95 % CI) is as follows: FEV1 < 80 %: 1.56(0.99-2.47), p = 0.056; FEV1/FVC < 0.70: 1.67(1.03-2.69), p = 0.037; FEF25-75 < 60 %: 1.84(1.18-2.86), p = 0.007; R5 > 150 %: 1.91(1.25-2.95), p = 0.003; and R5-R20 > 0.1 kPa L(-1) s 1.73(1.12-2.66), p = 0.013. For SABA use, the adjusted OR (95 % CI) is as follows: FEV1 < 80 %: 2.22(1.43-3.44), p < 0.001; FEV1/FVC < 0.70: 2.26(1.44-3.57), p < 0.001; FEF25-75 < 60 %: 2.51(1.65-3.82), p < 0.001; R5 > 150 %: 1.76(1.18-2.63), p = 0.006; and R5-R20 > 0.1 kPa L(-1) s: 2.94(1.94-4.46), p < 0.001.

Conclusion: Spirometry or IOS measurements were equally useful as potential markers of asthma control in persistent asthmatic patients.

PubMed Disclaimer

References

    1. J Allergy Clin Immunol. 2013 Mar;131(3):718-23 - PubMed
    1. Lancet Respir Med. 2014 Jun;2(6):497-506 - PubMed
    1. Eur Respir J. 2008 Jan;31(1):143-78 - PubMed
    1. Chest. 2002 Jun;121(6):1824-32 - PubMed
    1. J Asthma. 2012 Aug;49(6):586-92 - PubMed

Publication types

MeSH terms

LinkOut - more resources