Comparative Study
. 2015 May;25(5):1392-8.
doi: 10.1007/s00330-014-3542-x. Epub 2014 Dec 19.

Assessing liver function in patients with HBV-related HCC: a comparison of T₁ mapping on Gd-EOB-DTPA-enhanced MR imaging with DWI

Affiliations
Comparative Study

Assessing liver function in patients with HBV-related HCC: a comparison of T₁ mapping on Gd-EOB-DTPA-enhanced MR imaging with DWI

Ying Ding et al. Eur Radiol. 2015 May.

Abstract

Objectives: To compare the potential of T1 mapping on gadoxetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) and diffusion-weighted imaging (DWI) for assessing liver function in patients with hepatitis B virus (HBV)-related hepatocellular carcinoma (HCC).

Methods: One hundred consecutive patients with known HBV-related HCCs were included. T1 relaxation time and apparent diffusion coefficient (ADC) of the liver were measured, and the reduction rate of T1 relaxation time (∆%) was calculated. T1 relaxation time measurements were compared with ADC values according to the Model for End-Stage Liver Disease (MELD) score.

Results: Hepatobiliary phase (HBP) and ∆% of T1 relaxation time measurements showed significant correlations with MELD score (rho = 0.571, p < 0.0001; rho = -0.573, p < 0.0001, respectively). HBP and ∆% of T1 relaxation time were significantly different between good (MELD ≤8) and poor liver function (MELD ≥9) (p < 0.0001 for both). Areas under the receiver operating characteristic curves (AUCs) of T1 relaxation time for HBP (AUC 0.84) and ∆% (AUC 0.82) were significantly better than for ADC (AUC 0.53; p < 0.0001).

Conclusions: T1 mapping on Gd-EOB-DTPA-enhanced MRI showed promise for evaluating liver function in patients with HBV-related HCC, while DWI was not reliable. HBP T1 relaxation time measurement was equally accurate as ∆% measurement.

Key points: • T 1 mapping on Gd-EOB-DTPA MRI was accurate for assessing liver function. • HBP T 1 relaxation time measurement was as accurate as ∆% T 1 • T 1 mapping on Gd-EOB-DTPA MRI was more accurate than DWI-ADC measurement.