Cyclic displacement after meniscal root repair fixation: a human biomechanical evaluation
- PMID: 25556220
- DOI: 10.1177/0363546514562554
Cyclic displacement after meniscal root repair fixation: a human biomechanical evaluation
Abstract
Background: Recent biomechanical evidence suggests that the meniscus-suture interface contributes the most displacement to the transtibial pull-out repair for meniscal root tears. Therefore, optimization of surgical technique at the meniscus-suture interface may minimize displacement and improve the strength of meniscal root repairs.
Purpose/hypothesis: The purpose of this study was to investigate the cyclic displacement and ultimate failure loads of 4 different meniscus-suture fixation techniques for posterior medial meniscal root repairs in human meniscus tissue. The hypothesis was that there would be no significant difference between the two simple sutures (TSS) technique and 3 other techniques in cyclic displacement or ultimate failure load.
Study design: Controlled laboratory study.
Methods: A total of 32 fresh-frozen, human, medial meniscal transplant specimens were randomly assigned to 4 meniscus-suture fixation techniques used for transtibial pull-out repair in posterior medial meniscal root tears (n = 8 per group). The suture techniques studied were (1) TSS, (2) modified Mason-Allen (MMA), (3) single double-locking loop (S-DLL), and (4) double double-locking loop (D-DLL). The menisci were subjected to a cyclic tensioning protocol representative of postoperative rehabilitation (10-30 N for 1000 cycles) and pulled to failure at a rate of 0.5 mm/s.
Results: After 1000 cycles, the TSS group displaced the least (mean ± SD, 1.78 ± 0.64 mm), followed by the MMA (2.14 ± 0.65 mm), D-DLL (2.97 ± 0.57 mm), and S-DLL (3.81 ± 0.78 mm) groups. After 100, 500, and 1000 cycles, suture displacements using the TSS and MMA techniques were not significantly different (P > .13), while the TSS technique resulted in significantly less displacement than the S-DLL and D-DLL (P < .03) techniques. The ultimate failure loads of the MMA (325 ± 77 N) and D-DLL (320 ± 50 N) techniques were significantly greater than those of the TSS (192 ± 52 N) and S-DLL (217 ± 51 N) techniques (P < .05).
Conclusion: The TSS and MMA fixation techniques were not significantly different, while the TSS was significantly better at resisting displacement when compared with the S-DLL and D-DLL stitch configurations. The MMA and D-DLL techniques exhibited significantly greater failure loads than did the TSS and S-DLL techniques; however, all techniques demonstrated ultimate failure loads above the currently accepted rehabilitation force threshold.
Clinical relevance: The TSS fixation technique combines the lowest technical difficulty and the ability to resist displacement at time zero. The MMA technique, although more technically challenging, may provide an alternative means to resist displacement while enhancing the failure load.
Keywords: meniscal repair; meniscus root; pull-out repair; root tears; sutures.
© 2015 The Author(s).
Similar articles
-
Biomechanical evaluation of different suture techniques for arthroscopic transtibial pull-out repair of posterior medial meniscus root tears.Am J Sports Med. 2013 Dec;41(12):2784-90. doi: 10.1177/0363546513502464. Epub 2013 Sep 6. Am J Sports Med. 2013. PMID: 24013348
-
A simple cinch is superior to a locking loop for meniscus root repair: a human biomechanical comparison of suture constructs in a transtibial pull-out model.Knee Surg Sports Traumatol Arthrosc. 2018 Aug;26(8):2239-2244. doi: 10.1007/s00167-017-4652-1. Epub 2017 Jul 26. Knee Surg Sports Traumatol Arthrosc. 2018. PMID: 28748490
-
A Novel Repair Method for Radial Tears of the Medial Meniscus: Biomechanical Comparison of Transtibial 2-Tunnel and Double Horizontal Mattress Suture Techniques Under Cyclic Loading.Am J Sports Med. 2016 Mar;44(3):639-45. doi: 10.1177/0363546515615565. Epub 2015 Dec 8. Am J Sports Med. 2016. PMID: 26646516
-
Modified Mason-Allen vs Two Simple Stitch Fixation for Medial Meniscus Posterior Root Tears: A Systematic Review and Meta-analysis.Am J Sports Med. 2024 Jun;52(7):1877-1887. doi: 10.1177/03635465231190650. Epub 2024 Jan 23. Am J Sports Med. 2024. PMID: 38258492
-
Biomechanical Properties of Posterior Meniscal Root Repairs: A Systematic Review.Arthroscopy. 2019 Jul;35(7):2189-2206.e2. doi: 10.1016/j.arthro.2019.01.018. Epub 2019 Apr 9. Arthroscopy. 2019. PMID: 30979628
Cited by
-
Medial Meniscus Posterior Root Tear: How Far Have We Come and What Remains?Medicina (Kaunas). 2023 Jun 21;59(7):1181. doi: 10.3390/medicina59071181. Medicina (Kaunas). 2023. PMID: 37511993 Free PMC article. Review.
-
Knotless Anchor Fixation for Transosseous Meniscal Root Repair Using Suture Tape Is Inferior Compared With Button or Screw Fixation: A Biomechanical Study.Orthop J Sports Med. 2020 Apr 20;8(4):2325967120912185. doi: 10.1177/2325967120912185. eCollection 2020 Apr. Orthop J Sports Med. 2020. PMID: 32341928 Free PMC article.
-
The role of suture cutout in the failure of meniscal root repair during the early post-operative period: a biomechanical study.Int Orthop. 2018 Apr;42(4):811-818. doi: 10.1007/s00264-018-3799-9. Epub 2018 Feb 2. Int Orthop. 2018. PMID: 29396804
-
Biomechanical analysis of four different meniscus suturing techniques for posterior meniscal root pull-out repair: A human cadaveric study.J Exp Orthop. 2024 Sep 23;11(3):e70020. doi: 10.1002/jeo2.70020. eCollection 2024 Jul. J Exp Orthop. 2024. PMID: 39318713 Free PMC article.
-
Biomechanical Comparison of an All-Inside Meniscal Repair Device Construct Versus Pullout Sutures for Arthroscopic Transtibial Repair of Posterior Medial Meniscus Root Tears: A Matched-Pair Cadaveric Study.Orthop J Sports Med. 2021 Apr 22;9(4):23259671211000464. doi: 10.1177/23259671211000464. eCollection 2021 Apr. Orthop J Sports Med. 2021. PMID: 33997064 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical