. 2015 Apr;34(4):833-42.
doi: 10.1002/etc.2865. Epub 2015 Feb 27.

Measurements of nanomaterials in environmentally relevant water matrices using liquid nebulization/differential mobility analysis

Affiliations

Measurements of nanomaterials in environmentally relevant water matrices using liquid nebulization/differential mobility analysis

Brian T Mader et al. Environ Toxicol Chem. 2015 Apr.

Abstract

A liquid nebulization-differential mobility analysis methodology was evaluated for the measurement of the size distribution and quantitative mass concentration of nanomaterials in environmentally relevant aqueous media. The analysis time is 8 min, and the method requires little routine sample preparation and less than 8 mL of sample. The method can be used for rapid, direct analysis of nanomaterials in aqueous media with a particular application to dose verification in ecotoxicology studies, analysis of manufacturing process waste streams, and raw material analysis. Twelve reference materials having a diameter traceable to the National Institute of Standards and Technology were spiked into 6 different aqueous matrices that included drinking water, groundwater, industrial wastewater, as well as the algae and daphnia media used in ecotoxicology testing. Measurement of the diameter of a reference material was within the expected range for the reference material. Individual response factors for each reference material were determined in each medium and the accuracy and precision of the concentration measurements evaluated. In ecotoxicology test media, measurements of the concentration of nanoparticles having diameter ≥ 30 nm, had corresponding accuracies and precisions of 103% and 7%, respectively. Over 28 d 86% of the samples had concentrations within 20% of the initial concentration. The method limit of quantification depended primarily on matrix complexity and particle diameter; the limit of quantification ranged from 0.01 mg/L to 3 g/L.

Keywords: Ecotoxicology; Nanomaterial; Nanoparticle; Toxicity; Validation.