Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2015 Sep;42(3):689-97.
doi: 10.1002/jmri.24833. Epub 2014 Dec 30.

Does a cleansing enema improve image quality of 3T surface coil multiparametric prostate MRI?

Affiliations

Does a cleansing enema improve image quality of 3T surface coil multiparametric prostate MRI?

Christopher Lim et al. J Magn Reson Imaging. 2015 Sep.

Abstract

Purpose: To assesses the utility of a preparatory enema in the interpretation of prostate multiparametric (MP) magnetic resonance imaging (MRI).

Materials and methods: Under a waiver from the Institutional Review Board (IRB), 32 patients without bowel preparation and 28 patients who underwent a self-administered enema were imaged consecutively with 3T MP-MRI over 6 months. Two blinded radiologists independently assessed image quality on T2 -weighted (T2 W), trace b 1000 mm(2) /sec echo-planar (EPI) and apparent-diffusion coefficient (ADC) and assessed for motion/blur on T2 W and distortion/blur on EPI and ADC. Radiologists also quantified rectal stool and gas. A third blinded radiologist generated contrast curves from dynamic contrast-enhanced (DCE) data at six locations and measured the number of corrupted data points, defined as >10% aberrant signal intensity change. Subjective scores were compared using Wilcoxon sign rank test. Rectal contents were correlated to artifact using Spearman correlation. Contrast curves were evaluated with independent t-tests.

Results: There was no difference in image quality on T2 W (P = 0.66-0.74), EPI (P = 0.13-0.36) or ADC (P = 0.49-0.59). There was less rectal stool in the enema group (P = 0.004) and amount of stool correlated with motion artifact on T2 W (r = 0.23, P = 0.02); however, there was no difference in motion artifact between groups (P = 0.47-0.94). Only a minority of patients in the non-enema group had moderate or large amounts of stool (16%) and none of these patients had severe or extensive artifact on T2 . There was less rectal gas in the enema group (P = 0.002); however, amount of gas did not correlate with distortion artifact on EPI or ADC (P = 0.17-0.41) and there was no difference in blur (P = 0.41-0.91) or distortion (P = 0.31-0.99) on EPI or ADC between groups. There was no difference in corrupted data points on DCE (P = 0.46).

Conclusion: In this study the use of a preparatory enema did not improve image quality or reduce artifact in prostate MP-MRI.

Keywords: diffusion weighted imaging; dynamic contrast enhancement; enema; magnetic resonance imaging; multiparametric; prostate.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources