. 2014 Dec;67(6):378-83.
doi: 10.4097/kjae.2014.67.6.378. Epub 2014 Dec 29.

The correlation between the Trendelenburg position and the stroke volume variation

Affiliations

The correlation between the Trendelenburg position and the stroke volume variation

Jin Hye Min et al. Korean J Anesthesiol. 2014 Dec.

Abstract

Background: The stroke volume variation (SVV), based on lung-heart interaction during mechanical ventilation, is a useful dynamic parameter for fluid responsiveness. However, it is affected by many factors. The aim of this study was to evaluate the effects of SVV on Trendelenburg (T) and reverse Trendelenburg (RT) position and to further elaborate on the patterns of the SVV with position.

Methods: Forty-two patients undergoing elective surgery were enrolled in this study. Fifteen minutes after standardized induction of anesthesia with propofol, fentanyl, and rocuronium with volume controlled ventilation (tidal volume of 8 ml/kg of ideal body weight, inspiration : expiration ratio of 1 : 2, and respiratory rate of 10-13 breaths/min), the patients underwent posture changes as follows: supine, T position at slopes of operating table of -5°, -10°, and -15°, and RT position at slopes of operating table of 5°, 10°, and 15°. At each point, SVV, cardiac output (CO), peak airway pressure (PAP), mean blood pressure, and heart rate (HR) were recorded.

Results: The SVV was significant decreased with decreased slopes of operating table in T position, and increased with increased slopes of operating table in RT position (P = 0.000). Schematically, it was increased by 1% when the slope of operating table was increased by 5°. But, the CO and PAP were significant increased with decreased slopes of operating table in T position, and decreased with increased slopes of operating table in RT position (P = 0.045, 0.027).

Conclusions: SVV is subjected to the posture, and we should take these findings into account on reading SVV for fluid therapy.

Keywords: Fluid therapy; Reverse Trendelenburg position; Stroke volume variation; Trendelenburg position.

PubMed Disclaimer

Figures

Fig. 1
Fig. 1
Stroke Volume Variation according to Posture. Data are presented as means ± SD. SVV increased with increasing slope of operating table, and these were statistically significant (P = 0.000). SVV: stroke volume variation. T-15: at -15° slope of an operating table in head-down tilt, T-10: at -10° slope of an operating table in head-down tilt, T-5: at -5° slope of an operating table in head-down tilt, T0: at 0° slope of an operating table in supine position, T5: at 5° slope of an operating table of -5° in head-up tilt, T10: at 10° slope of an operating table in head-up tilt, and T15: at 15° slope of an operating table in head-up tilt.

Similar articles

Cited by

References

    1. Donati A, Loggi S, Preiser JC, Orsetti G, Münch C, Gabbanelli V, et al. Goal-directed intraoperative therapy reduces morbidity and length of hospital stay in high-risk surgical patients. Chest. 2007;132:1817–1824. - PubMed
    1. Michard F, Teboul JL. Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence. Chest. 2002;121:2000–2008. - PubMed
    1. Zhang Z, Lu B, Sheng X, Jin N. Accuracy of stroke volume variation in predicting fluid responsiveness: a systematic review and meta-analysis. J Anesth. 2011;25:904–916. - PubMed
    1. Kim KM, Gwak MS, Choi SJ, Kim MH, Park MH, Heo BY. Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy. Korean J Anesthesiol. 2013;65:237–243. - PMC - PubMed
    1. Kim HK, Pinsky MR. Effect of tidal volume, sampling duration, and cardiac contractility on pulse pressure and stroke volume variation during positive-pressure ventilation. Crit Care Med. 2008;36:2858–2862. - PMC - PubMed